Pengaruh Laju Aliran Air terhadap Temperatur Sistem Mesin Pengkondisian Udara Hibrida Menggunakan Kondensor Dummy Tipe Helical Coil (Diameter Pipa 1/4') sebagai Water Heater dengan Pembebanan 2000 Watt

机译:流量对螺旋盘绕型冷凝器(管径1/4“)为2000瓦热水的混合空调系统温度的影响。

摘要

Energy saving is one way to reduce energy USAge without decreasing the results. This way can be obtained byusing the hybrid air conditioning. Other than energy saving, the hybrid air conditioning also can reduce theeffects of global warming by condenser waste heat recovery. This research aims to investigate the effect ofvariations flow rate in water heater tank to the system temperatures of hybrid air conditioning using helical coiltype of dummy condenser with 1/4˝ diameter of copper pipe. Experimental method is used in this research. Thetest was conducted with several water flow rate variations (1/3, 2/3, and 3/3 valve openings) and using coolingload of 2000 Watt as residential cooling load simulation. The result showed that the water temperature in waterheater tank was changed in every water flow rate variations. The highest water temperature was obtained at39.77˚C for 0 valve opening (full-closed valve), but, the lowest water temperature was obtained at 32.57˚C in3/3 valve opening (full-open valve).
机译:节能是减少能耗但不降低结果的一种方法。通过使用混合空调可以获得这种方式。除了节能以外,混合空调还可以通过冷凝器废热回收来降低全球变暖的影响。本研究的目的是研究螺旋直径为1 /4˝的铜管虚设冷凝器的螺旋盘绕型,热水器水箱中的流量变化对混合空调系统温度的影响。本研究采用实验方法。在几个水流量变化(1 / 3、2 / 3和3/3阀门开度)的情况下进行了该测试,并使用2000瓦的冷却负荷作为住宅的冷却负荷模拟。结果表明,热水器水箱温度随水流量的变化而变化。 0阀开度(全开阀)的最高水温为39.77˚C,3/3阀开度(全开阀)的最低水温为32.57˚C。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号