>Pengaruh Beban Pendinginan terhadap Temperatur Sistem Residential Air Conditioning Hibrida dengan Kondensor Dummy Tipe Trombone Coil Menggunakan Refrigeran Hidrokarbon
【2h】
Pengaruh Beban Pendinginan terhadap Temperatur Sistem Residential Air Conditioning Hibrida dengan Kondensor Dummy Tipe Trombone Coil Menggunakan Refrigeran Hidrokarbon
An experimental study in the hybrid air conditioning machine as air conditioner and water heater by retrofitting R-22 with hydrocarbon refrigerant (HCR-22) have been investigated. Drop-in experiments were carried out without any modification on the system. The system has been tested by varying the internal heat load 0, 1000, 2000, and 3000 W for residential cooling load simulation. The measurements taken during two hour experimental periods at 5 minutes interval times for temperature set point of 19°C. Temperature of the system is the objective of this research. The result shows refrigerant temperature of HCR-22 lower than R-22 because differences of compressor discharge pressure. Temperature discharge decrease between 16.22-24.02 ˚C. For conditioned room, room temperature in every internal heat load was relative same. And water temperature in 50 L storage are 46.58-48.81 ˚C.