In the Air Conditioning engine, the resulting cooling effect is used to cool the room and the heat effect that is simply thrown into the environment. While, the Hybrid Residential Air Conditioning machine is utilizes the cooling effect and the simultaneous heating effect of the refrigeration machine. Chiller is a cooling system that uses cooling media (water or brine) and HCR-22 as a working fluid. The purpose of this study is to determine the consumption of electrical energy, by using standby mode method with 1000 Watt cooling load in this research got the average value Coefficient Of Performance (COP) of 2.471, average value Performance of Factor(PF) of 3.43, average value Total of Performance (TP) of 5.90. For the average temperature in the cooling chamber is 28.20 0C, the average temperature in the heating chamber is 44.64 0C, with an average compressor power of 1.2680 kW and electricity consumption in 2 hours of working of 2.5359 kWh.
机译:在空调引擎中,所产生的冷却效果用于冷却房间,而热效果只是被扔到环境中。同时,混合住宅空调机利用了制冷机的冷却效果和同时加热的效果。冷水机组是一种冷却系统,使用冷却介质(水或盐水)和HCR-22作为工作流体。这项研究的目的是确定电能消耗,通过使用具有1000瓦制冷负载的待机模式方法,本研究获得的平均性能系数(COP)为2.471,平均值的性能系数(PF)为3.43 ,平均值为5.90。对于冷却室中的平均温度为28.20 0C,加热室中的平均温度为44.64 0C,压缩机的平均功率为1.2680 kW,工作2小时的耗电量为2.5359 kWh。