An interlaboratory comparison was organized among 71 environmental radioactivity monitoring laboratories for the determination of gross alpha/beta activity concentration in drinking water. The performance of participating laboratories was evaluated with respect to the reference values using relative deviations. Sample preparation and measurement methods used by the participating laboratories are detailed, in particular in view of method-dependency of the results. Many of the participants’ results deviate by more than two orders of magnitude from the reference values. This clearly demonstrates gross methods as unreliable and inaccurate in its present form and suggests revising the written standards for gross methods and restricting their application under clearly defined rules. Repeating this interlaboratory comparison is considered.
机译:在71个环境放射性监测实验室之间组织了实验室间比较,以确定饮用水中的总α/β活性浓度。使用相对偏差相对于参考值评估了参与实验室的性能。详细介绍了参与实验室使用的样品制备和测量方法,尤其是考虑到结果的方法依赖性。许多参与者的结果与参考值相差两个数量级以上。这清楚地表明总体方法不可靠且不准确,并建议修改总体方法的书面标准并限制其在明确定义的规则下的应用。考虑重复这种实验室间的比较。