Detection of residual neuroblastoma cells in bone marrow: comparison of flow cytometry with immunocytochemistry.

机译:检测骨髓中残留的神经母细胞瘤细胞:流式细胞术与免疫细胞化学的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: Because the cytomorphologic examination of bone marrow (BM) aspirates appears not sensitive enough to detect residual neuroblastoma cells, two four-color flow cytometric assays using different combinations of CD9, CD81, CD56, CD45, and anti-GD2 were evaluated. METHODS: The sensitivity of the flow cytometric assays was assessed by spiking experiments in normal peripheral blood samples. Twenty-eight BM samples, 12 biopsies, and 3 peripheral blood stem cell (PBSC) preparations from 22 patients with neuroblastoma were analyzed. The results were compared with those of an anti-GD2 immunocytochemical reference assay. RESULTS: Flow cytometric and immunocytochemical analyses showed residual neuroblastoma cells in four BM samples. One PBSC preparation and 20 BM samples were negative for both assays. Four BM and two PBSC samples scored positive for the immunocytochemical assay but were negative for the flow cytometric tests. This was due to the limited number of cells that were flow cytometrically analyzed. A strong correlation between the flow cytometric and immunocytochemical tests was found (chi2 = 6.4, P = 0.011). CONCLUSIONS: When an equal amount of cells is analyzed, the sensitivity of the flow cytometric assays is to be about 10 times lower than that of the immunocytochemical test. However, the flow cytometric assays can be used to screen for residual cells in clinical samples with a sensitivity of one neuroblastoma cell in 10(4) to 10(5) normal mononuclear cells. Flow cytometry is simple, quick, and cost effective compared with immunocytochemistry. In addition, the flow cytometric assays can be used to screen for residual neuroblastoma cells in case of a GD2-negative primary tumor. Therefore we recommend flow cytometry for the detection of residual neuroblastoma cells.
机译:背景:由于骨髓抽吸物的细胞形态学检查似乎不够灵敏,无法检测残留的神经母细胞瘤细胞,因此对使用CD9,CD81,CD56,CD45和抗GD2的不同组合的两种四色流式细胞术进行了评估。方法:通过加标实验在正常外周血样本中评估流式细胞仪测定的敏感性。分析了22例神经母细胞瘤患者的28份BM样品,12份活检标本和3份外周血干细胞(PBSC)制剂。将结果与抗GD2免疫细胞化学参考测定的结果进行比较。结果:流式细胞仪和免疫细胞化学分析显示在四个BM样品中残留了神经母细胞瘤细胞。两种测定中,一种PBSC制剂和20个BM样品均为阴性。四个BM和两个PBSC样本的免疫细胞化学分析得分为阳性,而流式细胞术测试则为阴性。这是由于流式细胞仪分析的细胞数量有限。发现流式细胞仪和免疫细胞化学测试之间有很强的相关性(chi2 = 6.4,P = 0.011)。结论:当分析相同数量的细胞时,流式细胞仪检测的灵敏度应比免疫细胞化学检测的灵敏度低约10倍。但是,流式细胞术可用于筛选临床样品中的残留细胞,其敏感性为10(4)至10(5)正常单核细胞中的一个神经母细胞瘤细胞。与免疫细胞化学相比,流式细胞术简单,快速且具有成本效益。另外,在GD2阴性的原发性肿瘤的情况下,流式细胞术可用于筛选残留的神经母细胞瘤细胞。因此,我们建议使用流式细胞仪检测残留的神经母细胞瘤细胞。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号