首页> 外文OA文献 >Validation of Three Body Composition Techniques with a Comparison of Ultrasound Abdominal Fat Depths against an Octopolar Bioelectrical Impedance Device
【2h】

Validation of Three Body Composition Techniques with a Comparison of Ultrasound Abdominal Fat Depths against an Octopolar Bioelectrical Impedance Device

机译:通过八极生物电阻抗仪比较超声腹部脂肪深度对三种人体成分技术的验证

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

International Journal of Exercise Science 5(3) : 205-213, 2012. The aims of this study were to cross-validate three clinical-grade measures of body composition, using an octopolar Bioelectrical Impedance (BIA), an ultrasound analyzer (US) and Air-Displacement Plethysmography (ADP) and second to compare the US scans of total abdominal, subcutaneous and visceral fat depths (mm) against the trunk percent fat (%BF) from the octopolar BIA. Twenty-six college-aged (22.9 ± 1.35 years) men (n = 18) and women (n = 8) volunteered to participate in this study. Body composition was assessed using BIA (total and by segments), ADP and US. In addition, total abdominal, subcutaneous and visceral fat layers were measured using the US. All measurements were done in accordance with manufacturers’ guidelines. The %BF comparing the three clinical grade machines were all significantly correlated and no significant differences were found using a 1-way ANOVA. All three fat depths were significantly correlated to the trunk fat % via BIA, while significant differences were found for the 1-way ANOVA. A Tukey post-hoc test showed significant differences between the BIA trunk %BF and both subcutaneous and visceral US fat depths. Having valid ways to measure body composition and visceral fat that is accessible in terms of being transportable, cost effective, and simple to use, should become a part of preventive medicine.
机译:International Journal of Exercise Science 5(3):205-213,2012年。本研究的目的是使用八极杆生物电阻抗(BIA),超声分析仪(US)对三种临床级别的身体成分进行交叉验证。以及空气排量脉搏描记术(ADP),其次是比较美国的腹部,皮下和内脏脂肪总深度(mm)与八极极BIA的躯干脂肪百分比(%BF)的美国扫描结果。 26名大学年龄(22.9±1.35岁)的男性(n = 18)和女性(n = 8)自愿参加了这项研究。身体成分使用BIA(总计和细分),ADP和US进行评估。另外,使用US测量腹部,皮下和内脏的总脂肪层。所有测量均按照制造商的指导原则进行。比较三台临床分级机的%BF均具有显着相关性,使用1向ANOVA分析则无显着差异。通过BIA,所有三个脂肪深度均与躯干脂肪%显着相关,而1向ANOVA则发现显着差异。 Tukey事后测试显示BIA躯干%BF与皮下和内脏US脂肪深度之间存在显着差异。具有可测量的身体成分和内脏脂肪的有效方法,可以运输,具有成本效益且易于使用,应该成为预防医学的一部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号