首页> 外文OA文献 >A new method for continuous measurement of methane and carbon dioxide in surface waters using off-axis integrated cavity output spectroscopy (ICOS): An example from the Baltic Sea
【2h】

A new method for continuous measurement of methane and carbon dioxide in surface waters using off-axis integrated cavity output spectroscopy (ICOS): An example from the Baltic Sea

机译:使用离轴集成腔输出光谱法(ICOS)连续测量地表水中甲烷和二氧化碳的新方法:以波罗的海为例

摘要

A new system is presented that allows the continuous measurement of methane and carbon dioxide concentrations in surface waters autonomously using ships of opportunity. The analytical setup consists of a methane carbon dioxide-Analyzer (MCA, Los Gatos Research) joined to an established equilibrator setup. The analyzer uses off-axis integrated cavity output spectroscopy (ICOS) and combines a highly specific infrared band laser with a set of strongly reflective mirrors to obtain an effective laser path length of several kilometers. This allows detecting methane and carbon dioxide in the equilibrated gas phase with high recision (less than 0.1%) and frequency.udThe system was installed on the cargo ship Finnmaid (Finnlines) in November 2009, which commutes regularly in the Baltic Sea between Travemünde (Germany), Gdynia (Poland), and Helsinki (Finland). Methane concentrations of the equilibrated gas phase measured by gas chromatography and by the MCA during lab tests are in excellent agreement. The comparison of carbon dioxide data measured by the MCA system to CO2 values gathered from the same type of equilibrator in combination with a LICOR CO2 detector (Schneider et al. 1992) during onboard operation show concordant results. The time constant for the system in freshwater at room temperature was determined to be 676 s for CH4 and 226 s for CO2. Additional performance tests are presented. First field results show large regional differences with remarkable features, especially in shallow regions, demonstrating the need for the high spatiotemporal data coverage provided by the instrument.
机译:提出了一个新系统,该系统允许使用机会船自动测量地表水中的甲烷和二氧化碳浓度。该分析装置由甲烷二氧化碳分析仪(MCA,Los Gatos Research)组成,并已建立平衡器。该分析仪使用离轴集成腔输出光谱(ICOS),并将高度特定的红外波段激光器与一组强反射镜结合在一起,可获得长达数公里的有效激光路径。这样可以在高精度气相色谱法(小于0.1%)和频率下检测平衡气相中的甲烷和二氧化碳。 ud该系统于2009年11月安装在Finnmaid(Finnlines)货船上,该船定期在波罗的海的特拉维明德之间往返(德国),格丁尼亚(波兰)和赫尔辛基(芬兰)。通过气相色谱法和MCA在实验室测试中测得的平衡气相的甲烷浓度非常吻合。在船上操作期间,将MCA系统测得的二氧化碳数据与从同一类型的平衡器结合LICOR CO2检测器(Schneider等,1992)收集的CO2值进行比较。在室温下,系统在淡水中的时间常数被确定为CH4为676 s,CO2为226 s。提出了其他性能测试。第一场结果表明,区域差异较大,具有明显的特征,尤其是在浅层地区,这表明需要仪器提供高时空数据覆盖率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号