This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar. A single-camera measuring system was used to record the in-plane deformation on the model surface at a frequency of 1.0 Hz under a load from 0 to 250 N. The images were then analyzed with specialist software to determine the direct (horizontal) and shear strains along the model. Not splinting the crowns resulted in higher stress transfer to the supporting implants when the second molar replica was absent. The presence of a second molar and an effective interproximal contact contributed to lower stress transfer to the supporting structures even for non-splinted restorations. Shear strains were higher in the region between the molars when the second molar was absent, regardless of splinting. The opposite was found for the region between the implants, which had higher shear strain values when the second molar was present. When an effective distal contact is absent, non-splinted implant-supported restorations introduce higher direct strains to the supporting structures under loading. Shear strains appear to be dependent also on the region within the model, with different regions showing different trends in strain changes in the absence of an effective distal contact. (C) 2011 Elsevier Ltd. All rights reserved.
机译:这项研究使用数字图像相关方法比较了有无近端接触的带夹和无夹植入物支持的假体。用下颌第一前磨牙和第二磨牙的丙烯酸树脂复制品,并用螺纹植入物代替第二前磨牙和第一磨牙,制成环氧树脂模型。制作带夹和不带夹的金属陶瓷螺钉固定牙冠,并在有和没有第二磨牙的情况下进行加载。使用单相机测量系统在0到250 N的负载下以1.0 Hz的频率记录模型表面上的平面内变形。然后使用专业软件分析图像以确定直接(水平)方向和水平方向。沿模型的剪切应变。当没有第二磨牙复制品时,不夹住牙冠会导致较高的应力转移到支撑种植体上。即使没有夹板的修复体,第二磨牙的存在和有效的近牙间接触也有助于将应力转移至支撑结构。当没有第二磨牙时,无论夹板如何,在磨牙之间的区域中的剪切应变都较高。在植入物之间的区域发现相反的情况,当存在第二磨牙时,该区域具有较高的剪切应变值。当缺少有效的远端接触时,无夹板的种植体支撑的修复体会在负载下对支撑结构产生更高的直接应变。剪切应变似乎也取决于模型中的区域,在没有有效的远端接触的情况下,不同区域显示出应变变化的不同趋势。 (C)2011 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号