A high-resolution powder diffractometer (HRPD) was installed on the IEA-R1 research reactor at IPEN-CNEN/SP, São Paulo, SP, Brazil. It is an extensive upgrade of the old IPEN-CNEN/SP multipurpose neutron diffractometer which used a single boron trifluoride (BF3) detector and a flat mosaic single crystal copper monochromator. The main modifications introduced were the installation of a position sensitive detector (PSD) and a focusing silicon monochromator. Placed at a distance of 1600 mm from sample, the PSD spans an angular range of 20° of a diffraction pattern. An extensive powder diffraction pattern can be obtained by collecting data in contiguous 20° segments. The double-focusing perfect single crystal silicon monochromator, installed in a take-off angle of 84°, can be positioned to produce 4 different wavelengths, namely 1.111, 1.399, 1.667 and 2.191 Å (nominal values). Diffraction patterns, obtained with the instrument, have shown a quite good resolution. Curves full width at half maximum (FWHM) vs. scattering angle (2θ) have been measured with powdered alumina using three vanadium sample holders 1/8, 1/4 and 3/8 in. in diameter. Such curves give the resolution that can be expected from the instrument in an interval 2θ from 5° to 130°. In comparison to the former instrument, the new diffractometer has much better resolution and is, per intensity point, ca. 600 times faster in data acquisition.
机译:高分辨率粉末衍射仪(HRPD)安装在位于巴西圣保罗的IPEN-CNEN / SP的IEA-R1研究堆上。它是对旧的IPEN-CNEN / SP多功能中子衍射仪的广泛升级,它使用了一个三氟化硼(BF3)检测器和一个平面镶嵌单晶铜单色仪。引入的主要修改是安装了位置敏感检测器(PSD)和聚焦硅单色仪。 PSD放置在距样品1600 mm的距离处,跨度为衍射图样20°的角度范围。通过在连续的20°分段中收集数据,可以获得广泛的粉末衍射图。可以以84°的起飞角安装的双聚焦完美单晶硅单色仪可以定位为产生4个不同的波长,即1.111、1.399、1.667和2.191Å(标称值)。用该仪器获得的衍射图样显示出相当好的分辨率。使用三个直径为1 / 8、1 / 4和3/8英寸的钒样品架,用粉末状氧化铝测量了半峰全宽(FWHM)与散射角(2θ)的曲线。这样的曲线可在5°至130°的2θ间隔内提供仪器预期的分辨率。与以前的仪器相比,新的衍射仪具有更好的分辨率,并且每个强度点大约为。数据采集​​速度提高600倍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号