首页> 外文OA文献 >Nondetection Index of Anti-Islanding Passive Protection of Synchronous Distributed Generators
【2h】

Nondetection Index of Anti-Islanding Passive Protection of Synchronous Distributed Generators

机译:同步分布式发电机抗孤岛被动保护非检测指标

摘要

Synchronous distributed generators are prone to operate islanded after contingencies, which is usually not allowed due to safety and power-quality issues. Thus, there are several anti-islanding techniques; however, most of them present technical limitations so that they are likely to fail in certain situations. Therefore, it is important to quantify and determine whether the scheme under study is adequate or not. In this context, this paper proposes an index to evaluate the effectiveness of anti-islanding frequency-based relays commonly used to protect synchronous distributed generators. The method is based on the calculation of a numerical index that indicates the time period that the system is unprotected against islanding considering the global period of analysis. Although this index can precisely be calculated based on several electromagnetic transient simulations, a practical method is also proposed to calculate it directly from simple analytical formulas or lookup tables. The results have shown that the proposed approach can assist distribution engineers to assess and set anti-islanding protection schemes.
机译:同步分布式发电机在意外事件之后易于孤岛运行,由于安全和电能质量问题,通常不允许这样做。因此,有几种防孤岛技术。但是,其中大多数存在技术限制,因此在某些情况下很可能会失败。因此,重要的是量化和确定所研究的方案是否适当。在这种情况下,本文提出了一种指标,用于评估通常用于保护同步分布式发电机的基于反孤岛频率的继电器的有效性。该方法基于数​​字索引的计算,该数字指示考虑到全局分析周期,系统不受保护的不受孤岛影响的时间段。尽管可以基于多个电磁暂态仿真精确地计算该指数,但也提出了一种实用的方法,可以直接从简单的分析公式或查找表中直接计算该指数。结果表明,所提出的方法可以帮助配电工程师评估和制定防孤岛保护方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号