The determination of the heat transfer coefficient of the pins of the Spallation Neutron Source is a very important problern for the development of this facility, as data for thermal and structural studies. Forthis purpose, a test apparatus was built, in scale 1 : 1, for the simulation of the thermal and hydraulical conditions of the Neutron Source. This apparatus is a pin bank, with one of the pins electrically heated. Performance of measurements gave the values for the heat transfer coefficient, here presented in the Nusselt Nurober form, and its local distribution. Results show the linear dependence of Nusselt Nurober on Reynolds Number, for a constant heat production.
机译:作为热学和结构研究的数据,确定散裂中子源的销的传热系数是该设施发展的一个非常重要的问题。为此目的,以1:1的比例建立了一个测试设备,用于模拟中子源的热和水力条件。该设备是一个针脚排,其中一个针脚被电加热。测量的性能给出了传热系数的值(此处以Nusselt Nurober形式表示)及其局部分布。结果表明,对于恒定的热量产生,Nusselt Nurober对雷诺数的线性依赖性。