首页> 外文OA文献 >Spaltproduktablagerung im Primärkreis des HTR bei extremen Corekühlungsstörfällen am Beispiel des PNP-500
【2h】

Spaltproduktablagerung im Primärkreis des HTR bei extremen Corekühlungsstörfällen am Beispiel des PNP-500

机译:以PNP-500为例,在极端堆芯冷却事故中,高温气冷堆主回路中的裂变产物沉积

摘要

This report presents an analysis of the consequences for the High Temperature Reactor PNP-500 which occur during core cooling accidents. The consequences of the temperature transients and the fission product behaviour are considered for the primary circuit. The analysis shows that, even for an extremely delayed start of the afterheat removal system, the retention of caesium in the graphite of the fuel elements and of the bottom reflector reduces the release of the coated particles by more than two orders of magnitude. The plate out in the steam generator leads temporarily to a further, however, much smaller retention of the release flow.
机译:该报告对堆芯冷却事故期间发生的高温反应堆PNP-500的后果进行了分析。对于主电路,要考虑温度瞬变和裂变产物行为的后果。分析表明,即使对于后排热系统的启动极为延迟,铯在燃料元件和底部反射器的石墨中的保留也会使涂层颗粒的释放减少两个数量级以上。蒸汽发生器中的积垢暂时导致释放流的进一步较小的保留。

著录项