首页> 外文OA文献 >Design of a regenerative load to increase efficiency during reliability testing of DC supply equipment
【2h】

Design of a regenerative load to increase efficiency during reliability testing of DC supply equipment

机译:设计可再生负载以提高直流电源设备可靠性测试期间的效率

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The paper is concerned with the design & construction of a regenerative load that redirects the electrical energy used for testing back to the grid instead of wasting it as heat. Manufacturers of DC supply equipment, such as DC power supplies and battery management units, apply burn-in testing at full load for 24 hours to detect early failures and reliability issues. The power drawn during full-load testing of DC supply equipment is normally dissipated into heat through resistive loads. The regenerative load has a very wide input voltage range to be able to test various models of DC supply equipment. The regenerative load consists of an efficient wide input voltage range DC-DC converter and a grid-connected inverter. This system will allow the energy drawn from the equipment under test to be fed back to the grid. The only energy consumed corresponds to the losses within the system.
机译:本文关注的是再生负载的设计和构造,该负载将用于测试的电能重新定向回电网,而不是将其浪费为热量。直流电源设备(例如直流电源和电池管理单元)的制造商在满负荷情况下进行老化测试24小时,以检测早期故障和可靠性问题。在直流电源设备的满载测试期间,汲取的功率通常通过电阻负载散发到热量中。再生负载具有非常宽的输入电压范围,可以测试各种型号的直流电源设备。再生负载由高效的宽输入电压范围DC-DC转换器和并网逆变器组成。该系统将允许从被测设备吸收的能量反馈到电网。消耗的唯一能量对应于系统内的损耗。