Evaluation of Modal and FEMA Pushover Procedures Using Strong-Motion Records of Buildings

机译:使用建筑物的强震动记录评估模态和FEMA推覆程序

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this investigation is to evaluate the FEMA-356 Nonlinear Static Procedure (NSP) and a recently developed Modal Pushover Analysis (MPA) procedure using recorded motions of four buildings that were damaged during the 1994 Northridge earthquake. For this purpose, displacements and drifts from the FEMA-356 NSP and the MPA procedures are compared with the values “derived” from the recorded motions. It is found that the FEMA-356 NSP typically underestimates the drifts in upper stories and overestimates them in lower stories when compared to the recorded motions. Among the four FEMA-356 distributions considered, the “Uniform” distribution led to the most excessive underestimation or overestimation indicating that the need to carefully reevaluate the usefulness of this distribution in the FEMA-356 NSP. Furthermore, FEMA-356 distributions failed to provide accurate estimates of story drifts for a building that satisfied the FEMA-356 criterion for detecting the presence of higher mode effects indicating the need to carefully re-examine this criterion. The MPA procedure, in general, provides estimates of the response that are much closer to the values from the recorded motion compared to those from the FEMA-356 NSP. In particular, the MPA procedure, unlike the FEMA-356 NSP, is able to capture the effects of higher modes. For a building that exhibits dominant effects of “soft” first story, however, neither the MPA procedure nor the FEMA-356 NSP led to reasonable estimate of the response.
机译:这项研究的目的是使用记录在1994年Northridge地震中受损的四栋建筑物的运动来评估FEMA-356非线性静态程序(NSP)和最近开发的模态推覆分析(MPA)程序。为此,将FEMA-356 NSP和MPA程序产生的位移和漂移与从记录的运动“得出”的值进行比较。发现与记录的动作相比,FEMA-356 NSP通常会低估上层的漂移,而高估下层的漂移。在所考虑的四个FEMA-356发行版中,“统一”发行版导致过高的低估或高估,这表明需要仔细地重新评估FEMA-356 NSP中该发行版的有效性。此外,FEMA-356发行版无法提供满足FEMA-356标准的建筑物的故事漂移的准确估计,该标准用于检测是否存在较高模式的影响,表明需要仔细地重新检查该标准。通常,与FEMA-356 NSP相比,MPA程序提供的响应估计值更接近记录的运动值。特别是,与FEMA-356 NSP不同,MPA程序能够捕获更高模式的影响。但是,对于一栋表现出“软”第一层建筑显性影响的建筑物,无论是MPA程序还是FEMA-356 NSP都无法合理估计响应。

著录项

  • 作者

    Goel, Rakesh K.;

  • 作者单位
  • 年度 2005
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号