首页> 外文OA文献 >THE BOND STRENGTH OF ADHESIVE RESIN CEMENT: TIME DIFFERENTIAL BETWEEN CEMENTATION AND FINISHING OF CAST DOWEL-CORES
【2h】

THE BOND STRENGTH OF ADHESIVE RESIN CEMENT: TIME DIFFERENTIAL BETWEEN CEMENTATION AND FINISHING OF CAST DOWEL-CORES

机译:胶粘剂水泥的粘结强度:胶结胶结的固结与精加工之间的时间差

摘要

THE BOND STREGTH OF ADHESIVE RESIN CEMENT: TIME DIFFERENTIAL BETWEEN CEMENTATION AND FINISHING OF CAST DOWEL-CORES By Purnima Joan Shahani, D.D.S., M.S.A Thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University.Virginia Commonwealth University, 2003Major Director: Peter C. Moon, M.S., PhDDirector of VCU Dental Biomaterials LaboratoryThis study compared the retention of cast dowel-cores cemented with Panavia® 21 subjected to immediate versus delayed high-speed finishing. Conventionally, finishing is delayed for 24 hours to one week to allow for optimal setting and ultimate strength of the cement. Forty-five recently extracted human maxillary canines were used. Teeth were divided among 3 groups: a control group (n=15, no finishing), an immediate finishing group (n=15, high-speed cutting of the cores performed five minutes after cementation) and a delayed finishing group (n=15, high-speed finishing performed 48 hours post-cementation). Tensile load to failure was applied using an Instron® at a crosshead speed of 0.05 inches/minute. A statistical test of equivalence was performed. The average retention force associated with failure after immediate finishing was not found to be inferior to delayed finishing failure force. In fact, post-hoc comparisons indicated that immediate finishing has statistically significant greater mean retentive force when compared to this force for delayed finishing at p = 0.00001.
机译:胶粘剂水泥的粘结强度:胶结水泥的固结和完成之间的时间差异作者:Purnima Joan Shahani,DDS,MSA联邦大学,2003年,主要负责人:Peter C.Moon,MS,PhD VCU Dental Biomaterials Laboratory主任本研究比较了用Panavia®21胶粘的铸造木钉芯在即时和延迟高速精加工下的保持力。通常,精加工会延迟24小时至一周,以实现最佳凝固和水泥最终强度。使用了四十五个最近提取的人类上颌犬。牙齿分为3组:对照组(n = 15,未完成),立即完成组(n = 15,在胶结后五分钟进行高速切削芯)和延迟完成组(n = 15) ,即在胶合后48小时进行的高速精加工)。使用Instron®以0.05英寸/分钟的十字头速度施加拉伸破坏载荷。进行了等效性的统计检验。没有发现与立即精加工后的失效相关的平均保持力不劣于延迟精加工的失效力。实际上,事后比较表明,与在p = 0.00001进行延迟精加工的力相比,立即精加工具有统计学上显着更大的平均保持力。

著录项

  • 作者

    Shahani Purnima Joan;

  • 作者单位
  • 年度 2003
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号