摘要

An expander is employed to replace a throttling valve in a heat pump system of the conventionorder to further improve the efficiency of the system by recovering partial expansion work to decconsume of the system. Due to large expansion ratios of conventional refrigerants, a twone-stage expander was proposed and designed. Simulation analysis was developed by analyzing irreversible losses in the expansion work process. The simulation results show that, friction losses of a conventional refrigerant expander are 80.2% of total losses, which are the main factors to influence the efficiency of expander. Then the measures of reduciong friction losses are presented, which would be expected to improve the expander efficiency efficiently.
机译:使用膨胀器代替常规顺序的热泵系统中的节流阀,以通过恢复部分膨胀功以减少系统消耗来进一步提高系统效率。由于常规制冷剂的膨胀比大,因此提出并设计了一种二级膨胀器。通过分析扩展工作过程中的不可逆损失来开发仿真分析。仿真结果表明,常规制冷剂膨胀机的摩擦损耗占总损耗的80.2%,这是影响膨胀机效率的主要因素。然后提出减少摩擦损失的措施,有望有效地提高膨胀机效率。