Refrigerant Charge Reduction In Small Commercial Refrigeration Systems

机译:小型商用制冷系统中的制冷剂费用减少

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper presents analysis of location of refrigerant inventory and experimental results of charge reduction in a typical bottle cooler with a finless condenser. The original unit was first characterized by determining its capacity, COP, pull-down characteristics and total charge using non-destructive instrumentation. After that the unit was instrumented by insertion of valves to separate main components and allow measurements of the charge in each of them, as well as pressure transducers, mass flow meter etc… Condenser is found to be the component that retains the most charge. The system was modelled using Engineering Equation Solver (EES) for performance and charge. Models are fully validated using steady state experimental results. Discussion of the results and direction for the charge reduction is provided.
机译:本文介绍了典型的带无翅式冷凝器的瓶式冷却器中制冷剂存量的位置分析和减少电荷的实验结果。最初的单位的特点是使用无损检测仪器确定其容量,COP,下拉特性和总电荷。此后,通过插入阀门以分离主要部件并允许测量每个部件中的电荷以及压力传感器,质量流量计等对仪器进行仪器化,发现冷凝器是保留最多电荷的部件。使用工程方程求解器(EES)对系统进行建模以提高性能和充电性能。使用稳态实验结果对模型进行了充分验证。提供了关于减少电荷的结果和方向的讨论。