摘要

The goal of this paper is to investigate the failure of a mandrel pin mounted on a rolling contact test bench. For this purpose, different methods of analysis were conducted, including metallography and stress analysis. The stress values in the failed pin were determined by Finite Elements. The high notch effect and the incorrect mounting of the specimens were identified as the failure causes. A pin design change is proposed to reduce the maximum stress even in the case of incorrect specimen mounting.
机译:本文的目的是研究安装在滚动接触试验台上的心轴销的故障。为此目的,进行了不同的分析方法,包括金相学和应力分析。失效销中的应力值由有限元确定。较高的缺口效应和不正确的试样安装被确定为失效原因。建议即使在样品安装不正确的情况下,也要更改销设计以减小最大应力。