首页> 外文OA文献 >Evaluation of a low-cost, low-power syringe pump to deliver magnesium sulfate intravenously to pre-eclamptic women in a Malawian referral hospital
【2h】

Evaluation of a low-cost, low-power syringe pump to deliver magnesium sulfate intravenously to pre-eclamptic women in a Malawian referral hospital

机译:评估在马拉维转诊医院为先兆子痫妇女静脉内输送硫酸镁的低成本,小功率注射泵

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background Magnesium sulfate is an affordable and effective treatment for pre-eclampsia and eclampsia. In settings where infusion pumps are not available to regulate the flow rate of intravenous delivery, healthcare providers must administer magnesium sulfate (MgSO4) via time-consuming and painful, large-volume intramuscular injections. As an alternative to costly commercially available syringe pumps, we developed AutoSyp, an accurate, low-cost, and low-powered syringe pump designed to meet the needs and constraints these low-resource settings. This paper describes results of a pilot study to evaluate the feasibility of using AutoSyp to administer MgSO4 intravenously to women suffering from pre-eclampsia at a referral hospital in Blantyre, Malawi. Methods AutoSyp was programmed to deliver MgSO4 following the Zuspan regimen to pregnant and post-partum women suffering from pre-eclampsia at Queen Elizabeth Central Hospital in Blatnyre, Malawi. Given the selection of either loading or maintenance dose on AutoSyp’s user interface, the flow rate was automatically programmed to dispense 60 mL/h or 5 mL/h of 20% MgSO4 solution, respectively. During each treatment, the dispensed volume was automatically calculated by the device based on the plunger position and stored on a computer for accuracy analysis of the mean flow rate and total volume delivered. The clinical results for both the loading and maintenance dose administrations were compared to the device’s accuracy during tests performed in the laboratory setting. Results Twenty-two women were enrolled in this study. In both the clinical and laboratory settings, the mean flow rate errors for the loading and maintenance dose infusions were under 2%. During 466 h of testing, the device sounded 129 occlusion alarms across 14 subjects. Of these, 71 alarms were false positives. Conclusion Results of this study support the use of AutoSyp as a less painful and accurate means of MgSO4 administration in clinical environments that lack infusion systems. There were a large number of false alarms in the current system which will be addressed in future designs. AutoSyp maintains the comfort of intravenous MgSO4 administration, but unlike commercially available syringe pumps, it is capable of operating with a variety of syringe brands and sizes and requires no additional consumables. AutoSyp’s appropriate design will benefit its implementation and sustained use in low-resource settings. Trial Registration Trial registered prospectively on November 18, 2014 with ClinicalTrials.gov ( NCT02296931 )
机译:摘要背景硫酸镁是治疗先兆子痫和子痫的一种经济有效的治疗方法。在无法使用输液泵调节静脉输注流速的环境中,医疗保健提供者必须通过费时且痛苦的大容量肌肉注射来施用硫酸镁(MgSO4)。作为昂贵的市售注射泵的替代产品,我们开发了AutoSyp,这是一种准确,低成本,低功率的注射泵,旨在满足这些低资源设置的需求和约束。本文介绍了一项初步研究的结果,以评估在马拉维布兰太尔的转诊医院使用AutoSyp静脉注射MgSO4对患有先兆子痫的女性的可行性。方法AutoSyp程序设计为在Zuspan方案后,向马拉维Blatnyre伊丽莎白女王中心医院的先兆子痫孕妇和产后妇女提供MgSO4。鉴于在AutoSyp的用户界面上选择了加载剂量或维持剂量,流速被自动编程为分别分配60 mL / h或5 mL / h的20%MgSO4溶液。在每次治疗过程中,设备将根据柱塞位置自动计算分配的体积,并将其存储在计算机中,以对平均流速和输送的总体积进行精确分析。在实验室环境下进行的测试中,将负荷和维持剂量给药的临床结果与设备的准确性进行了比较。结果本研究纳入了22名女性。在临床和实验室环境下,输注和维持剂量输注的平均流速误差均低于2%。在466小时的测试中,该设备在14个受试者身上发出了129次阻塞警报。其中,有71条警报为误报。结论这项研究的结果支持在缺乏输注系统的临床环境中使用AutoSyp作为无痛,准确的MgSO4给药方式。当前系统中存在大量错误警报,将在以后的设计中解决。 AutoSyp保持了MgSO4静脉内给药的舒适性,但与市售的注射泵不同,它能够与多种注射器品牌和尺寸一起使用,并且不需要其他消耗品。 AutoSyp的适当设计将有利于其在资源匮乏的环境中的实施和持续使用。试验注册该试验已于2014年11月18日在ClinicalTrials.gov上进行了预先注册(NCT02296931)

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号