首页> 外文OA文献 >A dosimetric retrospective planning study comparing volumetric arc therapy (VMAT) and stereotactic body radiotherapy (SBRT) treatment plans for non-small cell lung cancer (NSCLC)
【2h】

A dosimetric retrospective planning study comparing volumetric arc therapy (VMAT) and stereotactic body radiotherapy (SBRT) treatment plans for non-small cell lung cancer (NSCLC)

机译:剂量学回顾性计划研究比较了非小细胞肺癌(NSCLC)的容积弧线疗法(VMAT)和立体定向放射疗法(SBRT)治疗计划

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose ududA retrospective planning study comparing volumetric arc therapy (VMAT) and stereotactic body radiotherapy (SBRT) treatment plans for non-small cell lung cancer (NSCLC).ududMethods and materials ududFive randomly selected early stage lung cancer patients were included in the study. For each patient, four plans were created: the SBRT plan and three VMAT plans using different optimisation methodologies. A total of 20 different plans were evaluated. The dose parameters of dose conformity results and the target dose constraints results were compared for these plans.ududResults ududThe mean planning target volume (PTV) for all the plans (SBRT and VMAT) was 18·3 cm3, with a range from 15·6 to 20·1 cm3. The maximum dose tolerance to 1 cc of all the plans was within 140% (84 Gy) of the prescribed dose, and 95% of the PTV of all the plans received 100% of the prescribed dose (60 Gy). In all the plans, 99% of the PTV received a dose >90% of the prescribed dose, and the mean dose in all the plans ranged from 67 to 72 Gy. The planning target dose conformity for the SBRT and the VMAT (0°, 15° collimator single arc plans and dual arc) plans showed the tightness of the prescription isodose conformity to the target.ududConclusions ududSBRT and VMAT are radiotherapy approaches that increase doses to small tumour targets without increasing doses to the organs at risk. Although VMAT offers an alternative to SBRT for NSCLC and the potential advantage of VMAT is the reduced treatment times over SBRT, the statistical results show that there was no significant difference between the SBRT and VMAT optimised plans in terms of dose conformity and organ-at-risk sparing.
机译:目的 ud ud比较非小细胞肺癌(NSCLC)的容积弧线疗法(VMAT)和立体定向放射疗法(SBRT)治疗计划的回顾性计划研究。 ud ud方法和材料 ud ud五种随机选择的早期肺癌癌症患者被纳入研究。为每个患者创建了四个计划:SBRT计划和使用不同优化方法的三个VMAT计划。总共评估了20个不同的计划。比较了这些计划的剂量符合性结果和目标剂量限制结果的剂量参数。 ud ud结果 ud ud所有计划(SBRT和VMAT)的平均计划目标体积(PTV)为18·3 cm3,范围从15·6到20·1 cm3。所有计划对1 cc的最大剂量耐受性都在规定剂量的140%(84 Gy)之内,并且所有计划的PTV的95%接受了规定剂量(60 Gy)的100%。在所有计划中,有99%的PTV接受的剂量大于规定剂量的90%,并且所有计划中的平均剂量在67至72 Gy之间。 SBRT和VMAT的计划目标剂量一致性(0°,15°准直仪单弧计划和双弧计划)显示处方等剂量符合目标的紧密度。 ud ud结论 ud udSBRT和VMAT是放射疗法这种方法可以增加对小肿瘤靶标的剂量,而不会增加对处于危险中的器官的剂量。尽管VMAT为NSCLC提供了SBRT的替代方法,并且VMAT的潜在优势是与SBRT相比治疗时间减少了,但统计结果表明SBRT和VMAT优化计划在剂量一致性和器官器官方面没有显着差异。保留风险。

著录项

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 入库时间 2022-08-20 20:48:27

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号