首页> 外文OA文献 >A software program to measure the three-dimensional length of the spine from radiographic images: Validation and reliability assessment for adolescent idiopathic scoliosis
【2h】

A software program to measure the three-dimensional length of the spine from radiographic images: Validation and reliability assessment for adolescent idiopathic scoliosis

机译:从放射线图像测量脊柱三维长度的软件程序:青少年特发性脊柱侧弯的验证和可靠性评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

\ud\ud - The aim of this study was to validate a new program which aims at measuring the three-dimensional length of the spine's midline based on two calibrated orthogonal radiographic images. The traditional uniplanar T1-S1 measurement method is not reflecting the actual three dimensional curvature of a scoliotic spine and is therefore not accurate. The Spinal Measurement Software (SMS) is an alternative to conveniently measure the true spine's length.\ud\ud\ud\ud - The validity, inter- and intra-observer variability and usability of the program were evaluated. The usability was quantified based on a subjective questionnaire filled by eight participants using the program for the first time. The validity and variability were assessed by comparing the length of five phantom spines measured based on CT-scan data and on radiographic images with the SMS. The lengths were measured independently by each participant using both techniques.\ud\ud\ud\ud - The SMS is easy and intuitive to use, even for non-clinicians. The SMS measured spinal length with an error below 2 millimeters compared to length obtained using CT scan datasets. The inter- and intra-observer variability of the SMS measurements was below 5 millimeters.\ud\ud\ud\ud - The SMS provides accurate measurement of the spinal length based on orthogonal radiographic images. The software is easy to use and could easily integrate the clinical workflow and replace current approximations of the spinal length based on a single radiographic image such as the traditional T1-S1 measurement.
机译:\ ud \ ud-这项研究的目的是验证一个新程序,该程序旨在基于两个校准的正交射线照相图像来测量脊柱中线的三维长度。传统的单平面T1-S1测量方法无法反映脊柱侧凸脊柱的实际三维曲率,因此不准确。脊柱测量软件(SMS)是方便地测量真实脊柱长度的替代方法。\ ud \ ud \ ud \ ud-评估了程序的有效性,观察者之间和观察者内部的变异性和可用性。可用性是根据由八位参与者首次使用该程序填写的主观问卷进行量化的。通过比较基于CT扫描数据和X射线照相图像与SMS测得的五个幻影棘的长度,评估其有效性和可变性。长度是由每个参与者使用这两种技术独立测量的。\ ud \ ud \ ud \ ud-即使对于非临床医生,SMS也易于使用和直观。与使用CT扫描数据集获得的长度相比,SMS测量的脊柱长度误差小于2毫米。 SMS的观察者之间和观察者内部变异小于5毫米。\ ud \ ud \ ud \ ud-SMS基于正交的放射线图像,可准确测量脊柱长度。该软件易于使用,并且可以轻松集成临床工作流程,并基于单个X射线图像(例如传统的T1-S1测量)替换当前的脊柱长度近似值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号