首页> 外文OA文献 >Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results
【2h】

Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results

机译:用于预测IMRT预处理质量保证结果的治疗计划复杂性指标

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The planning of IMRT treatments requires a compromise between dose conformity (complexity) and deliverability. This study investigates established and novel treatment complexity metrics for 122 IMRT beams from prostate treatment plans. The Treatment and Dose Assessor software was used to extract the necessary data from exported treatment plan files and calculate the metrics. For most of the metrics, there was strong overlap between the calculated values for plans that passed and failed their quality assurance (QA) tests. However, statistically significant variation between plans that passed and failed QA measurements was found for the established modulation index and for a novel metric describing the proportion of small apertures in each beam. The ‘small aperture score’ provided threshold values which successfully distinguished deliverable treatment plans from plans that did not pass QA, with a low false negative rate.
机译:IMRT治疗的计划要求在剂量一致性(复杂性)和可传递性之间做出折衷。这项研究调查了来自前列腺治疗计划的122条IMRT光束的既定和新颖的治疗复杂性指标。使用“治疗和剂量评估者”软件从导出的治疗计划文件中提取必要的数据并计算指标。对于大多数指标,通过和未通过质量保证(QA)测试的计划的计算值之间存在很大的重叠。但是,对于已建立的调制指数和描述每个光束中小孔径比例的新颖度量,发现通过和未通过QA测量的计划之间存在统计学上的显着差异。 “小孔径得分”提供了阈值,可以成功地将可交付治疗计划与未​​通过质量检查的计划区分开来,假阴性率低。