This thesis is a documented energy audit and long term study of energy and water reduction in a ghee factory. Global production of ghee exceeds 4 million tonnes annually. The factory in this study refines dairy products by non-traditional centrifugal separation and produces 99.9% pure, canned, crystallised Anhydrous Milk Fat (Ghee). Ghee is traditionally made by batch processing methods. The traditional method is less efficient, than centrifugal separation.ududAn in depth systematic investigation was conducted of each item of major equipment including; ammonia refrigeration, a steam boiler, canning equipment, pumps, heat exchangers and compressed air were all fine-tuned. Continuous monitoring of electrical usage showed that not every initiative worked, others had pay back periods of less than a year. In 1994-95 energy consumption was 6,582GJ and in 2003-04 it was 5,552GJ down 16% for a similar output. ududA significant reduction in water usage was achieved by reducing the airflow in the refrigeration evaporative condensers to match the refrigeration load. Water usage has fallen 68% from18ML in 1994-95 to 5.78ML in 2003-04.udud The methods reported in this thesis could be applied to other industries, which have similar equipment, and other ghee manufacturers.
机译:本文是一份文件化的能源审计报告,是对酥油厂节能减排的长期研究。全球酥油产量每年超过400万吨。本研究中的工厂通过非传统的离心分离法精制乳制品,并生产99.9%的纯净,罐装,结晶无水乳脂(Ghee)。传统上,酥油是通过批处理方法制成的。传统方法比离心分离效率低。 ud ud对主要设备的每一项进行了深入的系统研究,包括:氨制冷,蒸汽锅炉,制罐设备,泵,热交换器和压缩空气都进行了微调。持续监控用电情况表明,并非每个计划都能奏效,其他计划的回收期不到一年。 1994-95年的能源消耗为6,582GJ,而2003-04年的能源消耗为5,552GJ,下降了16%。 ud ud通过减少制冷蒸发冷凝器中的气流以匹配制冷负荷,可以显着减少用水量。用水量已从1994-95年的18 ML下降到2003-04的5.78 ML,下降了68%。

著录项

  • 作者

    Markwell Darryl;

  • 作者单位
  • 年度 2005
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号