首页> 外文OA文献 >Bolted beam-column moment connections between cold-formed steel members
【2h】

Bolted beam-column moment connections between cold-formed steel members

机译:冷弯型钢构件之间的螺栓连接的梁柱弯矩连接

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

ABSTRACT Twelve beam-to-column connections between cold-formed steel sections consisting of three beam depths and four connection types were tested in isolation to investigate their behavior based on strength, stiffness and ductility. Resulting moment-rotation curves indicate that the tested connections are efficient moment connections where moment capacities ranged from about 65% to 100% of the connected beam capac-ity. With a moment capacity of greater than 80% of connected beam member capacity, some of the connec-tions can be regarded as full strength connections. Connections also possessed sufficient ductility with rota-tions of 20 mRad at failure although some connections were too ductile with rotations in excess of 30 mRad. Generally, most of the connections possess the strength and ductility to be considered as partial strength con-nections. The ultimate failures of almost all of the connections were due to local buckling of the compression web and flange elements of the beam closest to the connection.
机译:摘要分别测试了由三个梁深度和四个连接类型组成的冷弯型钢之间的十二个梁对柱连接,以基于强度,刚度和延性研究其行为。由此产生的力矩-旋转曲线表明,所测试的连接是有效的力矩连接,其力矩容量范围为所连接光束容量的65%至100%。当弯矩承载力大于连接梁构件承载力的80%时,某些连接可以视为全强度连接。连接也具有足够的延展性,故障时旋转为20 mRad,尽管某些连接的延展性超过30 mRad。通常,大多数连接都具有被视为部分强度连接的强度和延展性。几乎所有连接的最终失败都是由于压缩腹板和梁中最靠近连接的法兰元件的局部弯曲引起的。

著录项

  • 作者

    Ahamed Hazlan; Mahendran Mahen;

  • 作者单位
  • 年度 2010
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号