摘要

Background: For two decades, EEG-based Brain-Computer Interface (BCI) systems have been widely studied in research labs. Now, researchers want to consider out-of-the-lab applications and make this technology available to everybody. However, medical-grade EEG recording devices are still much too expensive for end-users, especially disabled people. Therefore, several low-cost alternatives have appeared on the market. The Emotiv Epoc headset is one of them. Although some previous work showed this device could suit the customer's needs in terms of performance, no quantitative classification-based assessments compared to a medical system are available.Methods: This paper aims at statistically comparing a medical-grade system, the ANT device, and the Emotiv Epoc headset by determining their respective performances in a P300 BCI using the same electrodes. On top of that, a review of previous Emotiv studies and a discussion on practical considerations regarding both systems are proposed. Nine healthy subjects participated in this experiment during which the ANT and the Emotiv systems are used in two different conditions: sitting on a chair and walking on a treadmill at constant speed.Results: The Emotiv headset performs significantly worse than the medical device; observed effect sizes vary from medium to large. The Emotiv headset has higher relative operational and maintenance costs than its medical-grade competitor.Conclusions: Although this low-cost headset is able to record EEG data in a satisfying manner, it should only be chosen for non critical applications such as games, communication systems, etc. For rehabilitation or prosthesis control, this lack of reliability may lead to serious consequences. For research purposes, the medical system should be chosen except if a lot of trials are available or when the Signal-to-Noise Ratio is high. This also suggests that the design of a specific low-cost EEG recording system for critical applications and research is still required. © 2013 Duvinage et al. licensee BioMed Central Ltd.
机译:背景:二十年来,基于EEG的脑机接口(BCI)系统已在研究实验室中得到广泛研究。现在,研究人员希望考虑实验室之外的应用程序,并将此技术提供给所有人。但是,对于最终用户,特别是残疾人,医疗级EEG记录设备仍然过于昂贵。因此,市场上出现了几种低成本的替代品。 Emotiv Epoc耳机就是其中之一。尽管以前的工作表明该设备可以满足客户在性能方面的需求,但与医疗系统相比,尚无基于定量分类的评估。方法:本文旨在统计比较医疗级系统,ANT设备和通过使用相同的电极在P300 BCI中确定其各自的性能,来制作Emotiv Epoc耳机。最重要的是,提出了对以前的动机研究的回顾,并讨论了关于这两种系统的实际考虑。 9名健康受试者参加了该实验,在此实验中,ANT和Emotiv系统在两种不同的条件下使用:坐在椅子上和以恒定速度在跑步机上行走。结果:Emotiv耳机的性能明显比医疗设备差;观察到的效应大小从中到大不等。 Emotiv耳机比其医疗级竞争对手具有更高的相对运营和维护成本。结论:尽管这款低成本耳机能够以令人满意的方式记录EEG数据,但仅应将其选择用于非关键性应用,例如游戏,通讯对于康复或假体控制,这种缺乏可靠性可能会导致严重的后果。出于研究目的,除非可以进行大量试验或信噪比高,否则应该选择医疗系统。这也表明仍然需要为关键应用和研究设计一种特定的低成本EEG记录系统。 ©2013 Duvinage等。被许可人BioMed Central Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号