This paper initially gives an introduction to ultra-high frequency (UHF) partial discharge monitoring techniques and their application to gas insulated substations. Recent advances in the technique, covering its application to power transformers, are then discussed and illustrated by means of four site trials. Mounting and installation of the UHF sensors is described and measurements of electrical discharges inside transformers are presented in a range of formats, demonstrating the potential of the UHF method. A procedure for locating sources of electrical discharge is described and demonstrated by means of a practical example where a source of sparking on a tap changer lead was located to within 15 cm. Progress with the development of a prototype on-line monitoring and diagnostic system is reviewed and possible approaches to its utilization are discussed. New concepts for enhancing the capabilities of the UHF technique are presented, including the possibility of monitoring the internal mechanical integrity of plant. The research presented provides sufficient evidence to justify the installation of robust UHF sensors on transformer tanks to facilitate their monitoring if and when required during the service lifetime.
机译:本文首先介绍了超高频(UHF)局部放电监测技术及其在气体绝缘变电站中的应用。然后,通过四个现场试验,讨论和说明了该技术的最新进展,涵盖了其在电力变压器中的应用。介绍了UHF传感器的安装和安装,并以多种格式表示了变压器内部的放电测量值,证明了UHF方法的潜力。通过一个实际示例描述并演示了定位放电源的过程,在该示例中,分接开关导线上的火花源位于15厘米以内。审查了原型在线监测和诊断系统的开发进展,并讨论了其利用的可能方法。提出了增强UHF技术功能的新概念,包括监视工厂内部机械完整性的可能性。提出的研究提供了充分的证据,可以证明在变压器油箱上安装了坚固的UHF传感器,以方便在使用寿命期间以及何时需要时对其进行监控。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号