首页> 外文OA文献 >Tensile properties of the transverse carpal ligament and carpal tunnel complex
【2h】

Tensile properties of the transverse carpal ligament and carpal tunnel complex

机译:腕横韧带和腕管复合体的拉伸特性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A new sophisticated method that uses video analysis techniques together with a Maillon Rapide Delta to determine the tensile properties of the transverse carpal ligament–carpal tunnel complex has been developed. Six embalmed cadaveric specimens amputated at the mid-forearm and aged (mean (SD)): 82 (6.29) years were tested. The six hands were from three males (four hands) and one female (two hands). Using trigonometry and geometry the elongation and strain of the transverse carpal ligament and carpal arch were calculated. The cross-sectional area of the transverse carpal ligament was determined. Tensile properties of the transverse carpal ligament–carpal tunnel complex and Load–Displacement data were also obtained. Descriptive statistics, one-way ANOVA together with a post-hoc analysis (Tukey) and t-tests were incorporated. A transverse carpal ligament–carpal tunnel complex novel testing method has been developed. The results suggest that there were no significant differences between the original transverse carpal ligament width and transverse carpal ligament at peak elongation (P= 0.108). There were significant differences between the original carpal arch width and carpal arch width at peak elongation (P=0.002). The transverse carpal ligament failed either at the mid-substance or at their bony attachments. At maximum deformation the peak load and maximum transverse carpal ligament displacements ranged from 285.74 N to 1369.66 N and 7.09 mm to 18.55 mm respectively. The transverse carpal ligament cross-sectional area mean (SD) was 27.21 (3.41)mm2. Using this method the results provide useful biomechanical information and data about the tensile properties of the transverse carpal ligament–carpal tunnel complex.
机译:已经开发了一种新的复杂方法,该方法使用视频分析技术以及Maillon Rapide Delta来确定腕横韧带-腕管复合体的拉伸性能。测试了六只在前臂中部和年龄(平均(SD)):82(6.29)岁时截肢的防腐尸体标本。六只手来自三只雄性(四只手)和一只雌性(两只手)。使用三角学和几何学,计算了腕腕横韧带和腕弓的伸长率和应变。确定腕横韧带的横截面积。还获得了腕腕横韧带-腕管复合体的拉伸特性和载荷-位移数据。描述性统计,单向方差分析,事后分析(Tukey)和t检验均纳入本文。已经开发了腕腕横韧带-腕管复合体的新测试方法。结果表明,原始的横腕韧带宽度和横腕韧带在峰值伸长率之间没有显着差异(P = 0.108)。原始腕骨弓宽度和腕骨弓宽度在峰值伸长率之间存在显着差异(P = 0.002)。腕横韧带在中段或在其骨附着处均失败。在最大变形时,峰值载荷和最大腕腕横韧带位移分别为285.74 N至1369.66 N和7.09 mm至18.55 mm。腕横韧带横截面积平均值(SD)为27.21(3.41)mm2。使用这种方法,结果提供了有用的生物力学信息和有关腕腕横韧带-腕管复合体的拉伸特性的数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号