首页> 外文OA文献 >Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxide
【2h】

Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxide

机译:评估和校准Aeroqual 500系列便携式气体传感器,以精确测量周围的臭氧和二氧化氮

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Low-power, and relatively low-cost, gas sensors have potential to improve understanding of intra-urban air pollution variation by enabling data capture over wider networks than is possible with 'traditional' reference analysers. We evaluated an Aeroqual Ltd. Series 500 semiconducting metal oxide O3 and an electrochemical NO2 sensor against UK national network reference analysers for more than 2months at an urban background site in central Edinburgh. Hourly-average Aeroqual O3 sensor observations were highly correlated (R2=0.91) and of similar magnitude to observations from the UV-absorption reference O3 analyser. The Aeroqual NO2 sensor observations correlated poorly with the reference chemiluminescence NO2 analyser (R2=0.02), but the deviations between Aeroqual and reference analyser values ([NO2]Aeroq-[NO2]ref) were highly significantly correlated with concurrent Aeroqual O3 sensor observations [O3]Aeroq. This permitted effective linear calibration of the [NO2]Aeroq data, evaluated using 'hold out' subsets of the data (R2≥0.85). These field observations under temperate environmental conditions suggest that the Aeroqual Series 500 NO2 and O3 monitors have good potential to be useful ambient air monitoring instruments in urban environments provided that the O3 and NO2 gas sensors are calibrated against reference analysers and deployed in parallel.
机译:与“传统”参考分析仪相比,低功率,相对低成本的气体传感器具有潜力,可以通过更广泛的网络捕获数据,从而提高对城市内部空气污染变化的了解。我们在英国爱丁堡市中心的城市背景下,针对英国国家网络参考分析仪对Aeroqual Ltd. 500系列半导体金属氧化物O3和电化学NO2传感器进行了2个月以上的评估。每小时平均Aeroqual O3传感器的观测值高度相关(R2 = 0.91),其幅度与来自UV吸收参考O3分析仪的观测值相似。 Aeroqual NO2传感器的观测值与参考化学发光NO2分析仪(R2 = 0.02)的相关性很差,但是Aeroqual和参考分析器值([NO2] Aeroq- [NO2] ref)之间的偏差与同时进行的Aeroqual O3传感器的观测值高度相关[ O3] Aeroq。这允许对[NO2] Aeroq数据进行有效的线性校准,并使用“保留”数据子集进行评估(R2≥0.85)。这些在温和环境条件下的现场观察表明,只要O3和NO2气体传感器已针对参考分析仪进行了校准并并行部署,Aeroqual 500系列NO2和O3监测仪就很有可能成为城市环境中有用的环境空气监测仪器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号