At present High Voltage Direct Current (HVDC) Voltage Source Converters (VSC) are susceptible dc faults leading to extreme currents. The fault current cannot be controlled by the converter switching flows in the anti-parallel diodes. Protection devices are, therefore, required to operate with sufficient speed to avoid device failure. A method is introduced to calculate the critical time for protection to operate. Using this method it is then shown how the critical time may be extended by way of optimization of passive system components. In order to perform this optimization a new post-fault (when the converter gating signals are inhibited) model of the Modular Multi-Level (MMC) converter is introduced which drastically reduces simulation time, allowing high resolution parameter sweeps to be performed. The model is validated and is shown to produce fault characteristics similar to that of a conventional switched model.
机译:目前,高压直流(HVDC)电压源转换器(VSC)易受直流故障影响,从而导致极端电流。故障电流不能通过反并联二极管中的转换器开关流来控制。因此,要求保护设备以足够的速度运行以避免设备故障。引入了一种方法来计算保护运行的关键时间。然后使用这种方法显示了如何通过优化无源系统组件来延长关键时间。为了执行此优化,引入了模块化多电平(MMC)转换器的新的故障后(当禁止转换器选通信号时)模型,该模型大大减少了仿真时间,从而可以执行高分辨率参数扫描。该模型经过验证,显示出与常规开关模型类似的故障特征。