This paper presents results of an experimental study of the behaviour of the stress variation at the flange of a gasketed and non-gasketed flanged pipe joints during both the bolt up (pre-loading) and operating (internal pressure loading) conditions. Stress variations showing flange yielding, flange rotation, effects of joint tightening sequence, identification of the mode of response to loading (static or dynamic) is discussed. In addition the effects of re-tightening, importance of high quality bolting with proper surface treatment and use of proper tooling are also discussed.
机译:本文介绍了在螺栓固定(预加载)和工作(内部压力加载)条件下,带垫片和非带垫片的法兰管接头法兰处的应力变化行为的实验研究结果。讨论了显示凸缘屈服,凸缘旋转,接头拧紧顺序的影响,对载荷响应模式(静态或动态)的识别的应力变化。此外,还讨论了重新拧紧的效果,采用适当的表面处理以及使用适当的工具进行高质量螺栓连接的重要性。