This paper is concerned with the development of a high-precision 30-kW (40-hp) calorimeter and is specifically focused on how experimental errors resulting from calorimeter design and operating procedures are eliminated or mitigated. A complete calibration for the calorimetric system using a dc heater is conducted, and two induction motors rated at 5.5 and 30 kW (7 and 40 hp, respectively) are carefully tested both within and outside of the calorimeter. Loss segregation is in accordance with the IEEE 112 method B. Experimental results for the comparison of calorimetric and input-output methods clearly confirm the effectiveness of the calorimeter in terms of accurate power loss measurement. The accuracy of the calorimeter is approximately 5.6 W in the measurement of power loss of up to 4.5 kW with a resolution of 0.1 W.
机译:本文关注于高精度30 kW(40 hp)量热仪的开发,特别关注如何消除或减轻由量热仪设计和操作程序引起的实验误差。使用直流加热器对量热系统进行了完整的校准,并在量热计的内部和外部仔细测试了两个额定功率分别为5.5和30 kW(分别为7和40 hp)的感应电动机。损耗隔离符合IEEE 112方法B。用于比较量热法和输入输出法的实验结果清楚地证实了量热仪在准确的功率损耗测量方面的有效性。在测量功率损耗高达4.5 kW,分辨率为0.1 W时,热量计的精度约为5.6W。