In this study, the sensitivity and the linearity of the un-coated and TiO2-coated microfiber knot resonator (MKR) have been analyzed. The MKR is very sensitive to humidity changes since its refractive index is strongly humidity dependent. As a result, shifts occur in the resonance wavelength and there are also changes in output power. The un-coated MKR showed a sensitivity of 1.3 pm/%RH, in terms of the resonance wavelength, and a sensitivity of 0.0626 dB/%RH for the transmitted output power. The sensitivity increased greatly after the deposition of a porous TiO2 nanoparticle coating on the MKR. The TiO2-coated MKR showed an improved sensitivity of 2.5 pm/%RH, with respect to the resonance wavelength, and 0.0836 dB/%RH for the transmitted output power. This MKR sensor has the potential for use in a variety of humidity sensing applications.
机译:在这项研究中,分析了未涂覆和TiO2涂覆的微纤维结谐振器(MKR)的灵敏度和线性。 MKR对折射率的变化非常敏感,因为它的折射率与湿度密切相关。结果,共振波长发生偏移,并且输出功率也发生变化。对于共振波长,未镀膜的MKR的灵敏度为1.3 pm /%RH,对于发射的输出功率,灵敏度为0.0626 dB /%RH。在MKR上沉积多孔TiO2纳米颗粒涂层后,灵敏度大大提高。相对于共振波长,涂有TiO2的MKR的灵敏度提高了2.5 pm /%RH,传输输出功率的灵敏度提高了0.0836 dB /%RH。该MKR传感器具有用于多种湿度传感应用的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号