首页> 外文OA文献 >Effects of load fluctuations on treatment potential of a hybrid sub-surface flow constructed wetland treating milking parlor waste water
【2h】

Effects of load fluctuations on treatment potential of a hybrid sub-surface flow constructed wetland treating milking parlor waste water

机译:负荷波动对混合地下水流人工湿地处理挤奶厅废水的处理潜力的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A hybrid sub-surface constructed wetland (CW) system consisting of 2 gravel filled vertical sub-surface (VFa & VFb) beds, each 160 m(2) in size planted with Phragmites australis and a sand filled horizontal sub-surface (HF) bed, 336 m(2) in size, planted with rice was operated from 2007 to 2010 for treating milking parlor waste water in Hokkaido, Japan. Hybrid CW system received huge fluctuations in average yearly inlet loads for TSS (526.0-1259 mg L-1 & 2.7-9.0 g m(-2) d(-1)), BOD5 (1,080-2,114 mg L-1 & 8.4-14.4 g m(-2) d(-1)), COD(1,962-7,085 mg L-1 & 14.5-50.0 g m(-2) d(-1)), TN (116.0-243.0 mg L-1 & 0.8-1.6 g m(-2) d(-1)), NH4-N (54.0-90.0 mg L-1 & 0.40-0.64 g m(-2) d(-1)), TC (1,022-2,215 mg L-1 & 6.0-15.1 g m(-2) d(-1)), TP (15.3-41.7 mg L-1 & 0.11-0.28 g m(-2) d(-1)) during study period. Average yearly purification and removal rates were least fluctuated for TSS (95.7-99.4%); moderately for BOD5 (86.1-95.7%), COD(87.5-96.1%) and TC (79.5-91.3%); highly for TN (72.6-90.6%), NH4-N (62.9-85.3%) and TP (64.8-87.2%). A sharp decrease in TP purification and removal rates were observed in 2008 due to sharp decrease in influent TP concentration in 2008 compared to 2007. OTR values for VF(a), VF(b), HF bed and total system were observed as 21.7, 19.3, 4.8 and 12.3 g O-2 m(-2) d(-1) respectively. Average k value of hybrid CW system for BOD5, TN, NH4-N and TP during study period were 7.0 +/- 1.8, 7.4 +/- 3.3, 5.6 +/- 4.1 and 4.9 +/- 2.0 m yr(-1) respectively. Average concentration of TSS, TP, TN and NH4-N in the final effluent for all years were below the discharge limit value of: 150 mg L-1 for TSS; 8 mg L-1 for TP, 60 mg L-1 for TN and NH4-N. However, average BOD5 and COD concentrations could not meet the discharge limit value of 120 mg L-1 during 2007 and 2008. (C) 2013 Elsevier B. V. All rights reserved.
机译:一种混合的地下人工湿地(CW)系统,包括2个砾石填充的垂直地下(VFa和VFb)床,每张床长160 m(2),种植了芦苇和沙子填充的水平地下(HF) 2007年至2010年,该工厂种植了336 m(2)的水稻床,用于处理日本北海道的挤奶厅废水。混合式CW系统的TSS(526.0-1259 mg L-1和2.7-9.0 gm(-2)d(-1)),BOD5(1,080-2,114 mg L-1和8.4-14.4)的年平均进口负荷受到巨大波动gm(-2)d(-1)),COD(1,962-7,085 mg L-1和14.5-50.0 gm(-2)d(-1)),TN(116.0-243.0 mg L-1和0.8-1.6 gm(-2)d(-1)),NH4-N(54.0-90.0 mg L-1和0.40-0.64 gm(-2)d(-1)),TC(1,022-2,215 mg L-1和6.0 -15.1 gm(-2)d(-1)),TP(15.3-41.7 mg L-1和0.11-0.28 gm(-2)d(-1))。 TSS的年均净化率和去除率波动最小(95.7-99.4%); BOD5(86.1-95.7%),COD(87.5-96.1%)和TC(79.5-91.3%)为中等; TN(72.6-90.6%),NH4-N(62.9-85.3%)和TP(64.8-87.2%)较高。由于2008年进水TP浓度与2007年相比急剧下降,2008年TP净化和去除率急剧下降。VF(a),VF(b),HF床和整个系统的OTR值为21.7,分别为19.3、4.8和12.3 g O-2 m(-2)d(-1)。研究期间BOD5,TN,NH4-N和TP的混合CW系统的平均k值分别为7.0 +/- 1.8、7.4 +/- 3.3、5.6 +/- 4.1和4.9 +/- 2.0 m yr(-1)分别。所有年份最终排放物中TSS,TP,TN和NH4-N的平均浓度均低于排放限值:TSS 150 mg L-1; TP为8 mg L-1,TN和NH4-N为60 mg L-1。但是,BOD5和COD的平均浓度在2007年和2008年不能达到120 mg L-1的排放极限值。(C)2013 Elsevier B. V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号