Single shear tests were conducted on nailed timber joints with varying main member thickness, side member thickness and nail length projecting from the main member, and their effects on various shear performances of nailed joints were investigated. Initial stiffness and yield load of nailed joints were almost constant when the ratio of main member thickness to nail diameter (lm/d) was 7-14 and 10-14, respectively. Maximum load and energy capacity increased as main member thickness was greater and showed the highest values when lm/d was 13-17 and 13-15. respectively. Maximum load of nailed joints with lm/d of 9 was 36% lower than that of nailed joints with lm/d of 13-17. Energy capacity of nailed joints with lm/d of 9 was 58% lower than that of nailed joints with lm/d of 13-15. Regardless of nail length projecting from the main member (lnp), initial stiffness of nailed joints with lnp was close to that of nailed joints without lnp. When the ratio of the sum of lm and lnp to nail diameter ratio (lr/d) was 10-11, maximum load and energy capacity of nailed joints with lnp were close to those of nailed joints without lnp. When lr/d was 12-15, maximum load and energy capacity of nailed joints with lnp were lower than those of nailed joints without lnp. When nailed joints have a member thickness according to the standard for structural design of timber structures edited by Architectural Institute of Japan, initial stiffness and yield load are little affected by member thickness but maximum load and energy capacity are greatly affected by member thickness.
机译:对钉木接头进行了单剪试验,钉木接头的主要构件厚度,侧面构件厚度和从主要构件伸出的钉子长度均发生变化,并研究了它们对钉接头的各种剪切性能的影响。当主要构件厚度与钉子直径的比值(lm / d)分别为7-14和10-14时,钉子的初始刚度和屈服载荷几乎恒定。当主要构件厚度增加时,最大载荷和能量容量增加,并且当lm / d为13-17和13-15时显示出最大值。分别。 lm / d为9的钉状关节的最大载荷比lm / d为13-17的钉状关节的最大载荷低36%。 lm / d为9的钉状接头的能量容量比lm / d为13-15的钉状接头的能量容量低58%。无论钉钉从主体(Inp)伸出的长度如何,带有lnp的钉接点的初始刚度都接近没有lnp的钉接点的刚度。当lm和lnp的总和与钉子直径之比(lr / d)为10-11时,带有lnp的钉式接头的最大载荷和能量容量接近没有lnp的钉式接头。当lr / d为12-15时,带有lnp的钉状关节的最大负荷和最大能量容量低于没有lnp的钉状关节。当钉接缝具有根据日本建筑学会编辑的木结构结构设计标准的构件厚度时,初始刚度和屈服荷载几乎不受构件厚度的影响,但是最大荷载和能量承载力却受到构件厚度的极大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号