首页> 外文OA文献 >Design and performance of hybrid constructed wetland systems for high-content wastewater treatment in the cold climate of Hokkaido, northern Japan
【2h】

Design and performance of hybrid constructed wetland systems for high-content wastewater treatment in the cold climate of Hokkaido, northern Japan

机译:日本北部北海道寒冷气候下用于高含量废水处理的混合人工湿地系统的设计和性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The performance of six multistage hybrid constructed wetland systems was evaluated. The systems were designed to treat four kinds of high-content wastewater: dairy wastewater (three systems, average inflow content 2,400-5,000 mg.COD l(-1), 3-6 years of operation); pig farm wastewater, including liquid food washing wastewater (one system, 9,500 mg.COD l(-1), 3 years); potato starch processing wastewater (one system, 20,000-60,000 mg.COD l(-1), 3 years); and wastewater containing pig farm swine urine (one system, 6,600 mg.COD l(-1), 2.8 years) (COD chemical oxygen demand). The systems contained three or four vertical (V) flow beds with self-priming siphons and surface partitions and no or one horizontal (H) flow bed (three to five beds). In some V flow beds, treated effluents were recirculated (Vr) through the inlet to improve performance. Mean annual temperature was 5-8 degrees C at all locations. To overcome clogging due to the high load in a cold climate, we applied a safety bypass structure and floating cover material to the V flow beds. Calculated average oxygen transfer rates (OTRs) increased proportionally with the influent load, and the OTR value was Vr > V > H. The relations of load-OTR, COD-ammonium, and a Arrhenius temperature-dependent equation enable the basic design of a reed bed system.
机译:评价了六个多级混合构造湿地系统的性能。该系统设计用于处理四种高含量废水:乳制品废水(三个系统,平均流入量为2,400-5,000 mg.COD l(-1),运行3-6年);猪场废水,包括液体食品洗涤废水(一种系统,9,500 mg.COD l(-1),3年);马铃薯淀粉加工废水(一套系统,20,000-60,000 mg.COD l(-1),3年);含猪场猪尿的废水(一套系统,6,600 mg.COD l(-1),2.8年)(COD化学需氧量)。该系统包含三个或四个带有自吸虹吸管和表面隔板的垂直(V)流化床,没有或只有一个水平(H)流化床(三至五个床)。在某些V型流化床中,经过处理的废水通过进口进行再循环(Vr),以提高性能。所有地点的年平均气温为5-8摄氏度。为了克服在寒冷气候下高负荷造成的堵塞,我们在V型流化床上应用了安全旁路结构和浮动盖材料。计算得出的平均氧气传输率(OTRs)与进水负荷成正比,OTR值Vr> V>H。负荷-OTR,COD-铵和Arrhenius依赖温度的方程式的关系使水的基本设计成为可能。芦苇床系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号