首页> 外文OA文献 >Design and Construction of a Novel Low-Cost Device to Provide Feedback on Manually Applied Forces
【2h】

Design and Construction of a Novel Low-Cost Device to Provide Feedback on Manually Applied Forces

机译:新型低成本装置的设计和构造,可提供手动作用力的反馈

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

STUDY DESIGN: Design and evaluation, technical note. OBJECTIVES: To describe the design of a simple, low-cost device for providing feedback of manually applied forces to the cervical spine, and to assess the device against specific design criteria. BACKGROUND: The forces applied during manual therapy may vary by as much as 500% between practitioners. But consistency can be improved in students when they are provided with contemporaneous feedback. The current methods of providing feedback, however, are expensive, complex, and/or preclude their performance in a clinically relevant manner. METHODS: The design of the device was assessed in accordance of the following criteria: (1) ease of use, (2) low cost, (3) minimal interference with technique, (4) ability to provide feedback with suitable accuracy at forces up to 50 N, and (5) no requirement of specialized skills to construct. RESULTS: A device is described that interfaces with standard computers through the sound card and measures force, using thin, low-cost, force-sensing resistors. Evaluated against the design criteria, the device (1) is easy to set-up and use, (2) can be produced for under $30 US dollars, (3) creates minimal interference with performance of a variety of techniques, (4) has limits of agreement from -3.8 to 4.2 N for forces of 5 to 45 N and repeatability coefficients of Ხ0 N or 12%, and (5) can be constructed without specialized skills or knowledge. CONCLUSION: A device is described that fulfills most of the design criteria for providing feedback on forces for physical therapy students and may have applications in other fields.
机译:研究设计:设计和评估,技术说明。目的:描述一种简单,低成本的设备的设计,该设备可提供手动施加的力到颈椎的反馈,并根据特定的设计标准评估该设备。背景:从业人员之间在手动治疗过程中施加的力可能相差多达500%。但是,当学生获得同期反馈时,可以提高他们的一致性。然而,当前提供反馈的方法昂贵,复杂和/或妨碍它们以临床相关的方式执行。方法:根据以下标准评估设备的设计:(1)使用简便,(2)成本低,(3)对技术的干扰最小,(4)在力向上时提供适当精度的反馈的能力到50 N,并且(5)不需要专门的技能来构建。结果:描述了一种通过声卡与标准计算机连接并使用薄的,低成本的力感测电阻器测量力的装置。根据设计标准进行评估,该设备(1)易于设置和使用,(2)的生产价格低于30美元,(3)对各种技术的性能产生的干扰最小,(4)具有对于5到45 N的力和Ხ0 N或12%的重复性系数,从-3.8到4.2 N的一致极限,并且(5)可以在没有专门技能或知识的情况下构造。结论:描述了一种满足大多数设计标准的设备,该设备可为物理治疗学生提供有关力的反馈,并且可能在其他领域中得到应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号