首页> 外文OA文献 >Global tidal variations, regional distribution of ventilation, and the regional onset of filling determined by electrical impedance tomography: reproducibility
【2h】

Global tidal variations, regional distribution of ventilation, and the regional onset of filling determined by electrical impedance tomography: reproducibility

机译:整体潮汐变化,通风区域分布以及由电阻抗层析成像确定的充盈区域开始:可再现性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The reproducibility of the regional distribution of ventilation and the timing of onset of regional filling as measured by electrical impedance tomography lacks evidence. This study investigated whether electrical impedance tomography measurements in healthy males were reproducible when electrodes were replaced between measurements. Part 1: Recordings of five volunteers lying supine were made using electrical impedance tomography and a pneumotachometer. Measurements were repeated at least three hours later. Skin marking ensured accurate replacement of electrodes. No stabilisation period was allowed. Part 2: Electrical impedance tomography recordings of ten volunteers; a 15 minute stabilisation period, extra skin markings, and time-averaging were incorporated to improve the reproducibility. Reproducibility was determined using the Bland-Altman method. To judge the transferability of the limits of agreement, a Pearson correlation was used for electrical impedance tomography tidal variation and tidal volume. Tidal variation was judged to be reproducible due to the significant correlation between tidal variation and tidal volume (r2 = 0.93). The ventilation distribution was not reproducible. A stabilisation period, extra skin markings and time-averaging did not improve the outcome. The timing of regional onset of filling was reproducible and could prove clinically valuable. The reproducibility of the tidal variation indicates that non-reproducibility of the ventilation distribution was probably a biological difference and not measurement error. Other causes of variability such as electrode placement variability or lack of stabilisation when accounted for did not improve the reproducibility of the ventilation distribution.
机译:缺乏证据表明通气区域分布的可再现性和通过电阻抗层析成像技术测量的区域充盈开始时间。这项研究调查了在两次测量之间更换电极后,健康男性的电阻抗层析成像测量是否可重现。第1部分:使用电阻抗断层扫描和气动测速仪对五名仰卧的志愿者进行记录。至少三小时后重复测量。皮肤标记确保了电极的准确更换。没有稳定期。第2部分:十位志愿者的电阻抗层析成像记录; 15分钟的稳定期,额外的皮肤痕迹和平均时间被纳入以提高可重复性。使用Bland-Altman方法确定可重复性。为了判断协议范围的可转移性,将皮尔逊相关性用于电阻抗层析成像的潮汐变化和潮气量。由于潮汐变化与潮气量之间存在显着相关性,因此潮汐变化被认为是可再现的(r2 = 0.93)。通风分布不可再现。稳定期,额外的皮肤斑纹和时间平均并不能改善结果。区域性充盈开始的时间是可重现的,并且可以证明具有临床价值。潮汐变化的可再现性表明通风分布的不可再现性可能是生物学差异,而不是测量误差。考虑到其他可变性原因,例如电极位置可变性或缺乏稳定性,并不能改善通气分布的可再现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号