Electromagnetic calorimeters based on dense, scintillating crystals have the potential to achieve extremely good energy resolution. However, care must be taken to minimise systematic effects such as variation of light collection efficiency with depth in the crystal. A HPMT has been used to accurately measure the non-uniformity of light collection in lead tungstate crystals for the CMS detector. It is found that the non-uniformity of crystals measured in the detector configuration is not much larger than the maximum tolerable limit. Shading the chamfered edges of the crystals with a pencil can reduce the non-uniformity by approximately 0.1%/X0. Roughening the chamfers achieves a similar reduction.
机译:基于致密,闪烁晶体的电磁量热仪具有实现极佳能量分辨率的潜力。但是,必须注意使系统影响最小化,例如集光效率随晶体深度的变化。 HPMT已被用于为CMS检测器准确测量钨酸铅晶体中光收集的不均匀性。发现在检测器配置中测量的晶体的不均匀性不比最大容许极限大很多。用铅笔遮挡晶体的倒角边缘可以将不均匀性降低约0.1%/ X0。粗加工倒角可以达到类似的效果。