Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer

机译:L3向前-向后Muon光谱仪的RPC的长期性能和后续实验室测试结果

摘要

The RPC chambers in the L3 forward-backward muon spectrometer have been operational from 1994 to the end of LEP running. After dismantling of the L3 detector some of the RPCs modules have been transported to Napoli where their performance has been re-measured with cosmic rays. Results of long-term performance in the LEP environment and of laboratory tests with cosmic rays will be presented. One of the 20 tested chambers, the one with the worst performances, was opened. The chamber was inspected with microscope and also a chemical analysis of the oil coating was performed. We will report in detail about this analysis.
机译:L3前后Muon光谱仪中的RPC室从1994年开始运行,直到LEP运行结束。拆除L3检测器后,一些RPCs模块已被运送到那不勒斯,在那里用宇宙射线重新测量了它们的性能。将介绍在LEP环境中的长期性能以及使用宇宙射线进行实验室测试的结果。打开了20个经过测试的腔室之一,其中一个性能最差。用显微镜检查腔室,并且还进行了油涂层的化学分析。我们将详细报告此分析。