Workstations and electronic display devices in a picture archiving and communication system (PACS) provide a convenient and efficient platform for medical diagnosis. The performance of display devices has to be verified to ensure that image quality is not degraded. In this study, we designed a set of randomized object test patterns (ROTPs) consisting of randomly located spheres with various image characteristics to evaluate the performance of a 2.5 mega-pixel (MP) commercial color LCD and a 3 MP diagnostic monochrome LCD in several aspects, including the contrast, resolution, point spread effect, and noise. The ROTPs were then merged into 120 abdominal CT images. Five radiologists were invited to review the CT images, and receiver operating characteristic (ROC) analysis was carried out using a five-point rating scale. In the high background patterns of ROTPs, the sensitivity performance was comparable between both monitors in terms of contrast and resolution, whereas, in the low background patterns, the performance of the commercial color LCD was significantly poorer than that of the diagnostic monochrome LCD in all aspects. The average area under the ROC curve (AUC) for reviewing abdominal CT images was 0.717±0.0200 and 0.740±0.0195 for the color monitor and the diagnostic monitor, respectively. The observation time (OT) was 145±27.6 min and 127±19.3 min, respectively. No significant differences appeared in AUC (p = 0.265) and OT (p = 0.07). The overall results indicate that ROTPs can be implemented as a quality control tool to evaluate the intrinsic characteristics of display devices. Although there is still a gap in technology between different types of LCDs, commercial color LCDs could replace diagnostic monochrome LCDs as a platform for reviewing abdominal CT images after monitor calibration.
机译:图片存档和通信系统(PACS)中的工作站和电子显示设备为医学诊断提供了方便而有效的平台。必须验证显示设备的性能,以确保图像质量不会下降。在这项研究中,我们设计了一组随机对象测试图案(ROTP),这些图案由具有各种图像特征的随机放置的球体组成,以评估2.5兆像素(MP)商业彩色LCD和3 MP诊断单色LCD的性能。方面,包括对比度,分辨率,点扩散效果和噪点。然后将ROTP合并为120幅腹部CT图像。邀请五位放射科医生检查CT图像,并使用五点评分量表进行接收器工作特征(ROC)分析。在ROTP的高背景图案中,在对比度和分辨率方面,两台显示器的灵敏度性能相当,而在低背景图案中,商用彩色LCD的性能在所有方面都显着低于诊断单色LCD的性能。方面。用于检查腹部CT图像的ROC曲线下的平均面积(AUC)对于彩色监视器和诊断监视器分别为0.717±0.0200和0.740±0.0195。观察时间(OT)分别为145±27.6分钟和127±19.3分钟。 AUC(p = 0.265)和OT(p = 0.07)没有显着差异。总体结果表明,可以将ROTP用作评估显示设备固有特性的质量控制工具。尽管不同类型的LCD之间在技术上仍然存在差距,但是商用彩色LCD可以代替诊断单色LCD,作为在监视器校准后查看腹部CT图像的平台。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号