首页> 外文OA文献 >Rapid Methods for Testing the Efficacy of Sterilization-Grade Filter Membranes
【2h】

Rapid Methods for Testing the Efficacy of Sterilization-Grade Filter Membranes

机译:快速测试灭菌级滤膜功效的方法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The validation of sterilization-grade membranes is integral to ensuring the efficient and safe use of microfiltration systems. Here validation refers to the production of sterile filtrate for sterilizing-grade membranes under challenge test conditions. Current validation methods require 48 h of culture for results to become available, which creates time delays within the manufacturing process and quality control (QC) backlogs. This work compares four methods for the production of filter challenge test data, to the desired test sensitivity, within 24 h using bioluminescent and fluorescent recombinant strains of the test organism Brevundimonas diminuta. These methods should provide a way to implement more rapid QC test regimens for filters.
机译:灭菌级膜的验证对于确保有效且安全地使用微滤系统至关重要。这里的验证是指在挑战性测试条件下生产用于无菌级膜的无菌滤液。当前的验证方法需要48小时的培养才能使结果可用,这会在制造过程和质量控制(QC)积压中造成时间延迟。这项工作使用测试生物Brevundimonas diminuta的生物发光和荧光重组菌株,在24小时内比较了四种产生过滤器质询测试数据的方法与所需的测试灵敏度。这些方法应提供一种为过滤器实施更快速的QC测试方案的方法。