首页> 外文OA文献 >Evaluation of the Etest ESBL and the BD Phoenix, VITEK 1, and VITEK 2 Automated Instruments for Detection of Extended-Spectrum Beta-Lactamases in Multiresistant Escherichia coli and Klebsiella spp.
【2h】

Evaluation of the Etest ESBL and the BD Phoenix, VITEK 1, and VITEK 2 Automated Instruments for Detection of Extended-Spectrum Beta-Lactamases in Multiresistant Escherichia coli and Klebsiella spp.

机译:评估Etest ESBL和BD Phoenix,VITEK 1和VITEK 2自动化仪器,以检测多重耐药性大肠杆菌和克雷伯氏菌属中的广谱β-内酰胺酶。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Seventy-four isolates of multiresistant Escherichia coli and Klebsiella spp. recovered during a 3-year period and 17 control strains with genotypically identified beta-lactamases were tested for the production of extended-spectrum beta-lactamases (ESBLs) by using the Etest and the VITEK 1, VITEK 2, and Phoenix automated instruments. The use of the Etest was evaluated by investigating its accuracy in detecting the ESBLs of the control strains and by comparing interpretation results of laboratory technicians and experts. The accuracy of the Etest was 94%. With the Etest as the reference for the clinical strains and the genotype as the reference for the control strains, the automated instruments detected the ESBLs with accuracies of 78% (VITEK 2), 83% (VITEK 1), and 89% (Phoenix). No significant difference between the systems with regard to the control strains was detected. The VITEK 2 did, however, perform less well than the Phoenix (P = 0.03) on the collection of clinical isolates, mainly because of its high percentage of indeterminate test results (11%). No significant difference between the performances of the VITEK 1 and either the VITEK 2 or the Phoenix was found. However, because of its associated BDXpert system the Phoenix showed the best performance. The Etest was found to be an accurate test but was limited by its indeterminate results (4%), its inability to differentiate between K1 hyperproduction and ESBLs, questionable guidelines concerning mutants inside the inhibition zones, and the inability of the technicians to recognize subtle zone deformations.
机译:多抗性大肠杆菌和克雷伯菌属的74种分离株。使用Etest和VITEK 1,VITEK 2和Phoenix自动仪器,对3年内回收的基因型已鉴定的17个对照菌株和具有基因型鉴定的β-内酰胺酶的超广谱β-内酰胺酶(ESBLs)进行了测试。通过研究Etest在检测对照菌株ESBLs中的准确性以及比较实验室技术人员和专家的解释结果,评估了Etest的使用。 Etest的准确性是94%。以Etest作为临床菌株的参考,以基因型作为对照菌株的参考,自动仪器检测到ESBL的准确度分别为78%(VITEK 2),83%(VITEK 1)和89%(Phoenix) 。在系统之间就对照菌株而言没有发现显着差异。但是,VITEK 2在临床分离株收集方面的表现不及Phoenix(P = 0.03),主要是因为其不确定的测试结果所占百分比很高(11%)。在VITEK 1和VITEK 2或Phoenix的性能之间没有发现显着差异。但是,由于其关联的BDXpert系统,Phoenix显示了最佳性能。发现Etest是一种准确的测试,但受到不确定的结果(4%),无法区分K1高产和ESBL的限制,有关抑制区内的突变体的可疑指南以及技术人员无法识别细微区域的限制,变形。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号