Evaluation of the Vitek 2 ID-GNB Assay for Identification of Members of the Family Enterobacteriaceae and Other Nonenteric Gram-Negative Bacilli and Comparison with the Vitek GNI+ Card

机译:用于鉴定肠杆菌科和其他非肠溶性革兰氏阴性杆菌成员的Vitek 2 ID-GNB分析的评估,并与Vitek GNI +卡进行比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated the Vitek 2 ID-GNB identification card (bioMérieux, Inc., Durham, N.C.) for its ability to identify members of the family Enterobacteriaceae and other gram-negative bacilli that are isolated in clinical microbiology laboratories. Using 482 enteric stock cultures and 103 strains of oxidase-positive, gram-negative glucose-fermenting and nonfermenting bacilli that were maintained at −70°C and passaged three times before use, we inoculated cards according to the manufacturer's directions and processed them in a Vitek 2 instrument using version VT2-R02.03 software. All panel identifications were compared to reference identifications previously confirmed by conventional tube biochemical assays. At the end of the initial 3-h incubation period, the Vitek 2 instrument demonstrated an accuracy of 93.0% for the identification of enteric strains; 414 (85.9%) were correctly identified at probability levels ranging from excellent to good, and an additional 34 (7.1%) strains were correctly identified but at a low level of discrimination. Nineteen (3.9%) strains were unidentified, and 15 (3.1%) were misidentified. The 19 unidentified strains were scattered among 10 genera. Three of the 15 misidentified strains were lactose-positive Salmonella spp. and were identified as Escherichia coli; another was a lactose-positive, malonate-negative Salmonella enterica subsp. arizonae strain that was identified as E. coli. Of the 103 glucose-fermenting and nonfermenting nonenteric strains, 88 (85.4%) were correctly identified at probability levels ranging from excellent to good, and 10 (9.7%) were correctly identified, but at a low level of discrimination, for a total of 95.1% accuracy with this group. Two strains were unidentified and three were misidentified. The errors occurred for strains in three different genera. With the increased hands-off approach of the Vitek 2 instrument and accuracies of 93% for the identification of enteric organisms and 95.1% for the identification of nonenteric organisms with the ID-GNB card, use of this product presents an acceptable method for the identification of most gram-negative organisms commonly isolated in the clinical laboratory. A comparison of these results to those obtained by testing 454 of the same strains with the Vitek GNI+ card revealed no significant difference in the abilities of the two cards to identify these organisms accurately.
机译:我们对Vitek 2 ID-GNB识别卡(bioMérieux,Inc.,Durham,N.C.)进行了评估,以鉴定其在临床微生物学实验室中分离出的肠杆菌科和其他革兰氏阴性杆菌家族成员的能力。使用482份肠库存培养物和103株氧化酶阳性,革兰氏阴性葡萄糖发酵和非发酵杆菌,它们保持在-70°C并在使用前经过3次传代,我们根据制造商的指示接种了卡片,并在使用版本VT2-R02.03的Vitek 2仪器。将所有小组鉴定结果与先前通过常规试管生化分析确认的参考鉴定结果进行比较。在最初的3小时孵育期结束时,Vitek 2仪器用于鉴定肠菌株的准确性为93.0%。正确鉴定出414株(85.9%)的概率范围从优良到良好,另外正确鉴定出34株(7.1%)菌株,但辨别率较低。未识别出19株(3.9%),错误识别了15株(3.1%)。 19株未鉴定菌株分散在10属中。 15个错误识别的菌株中有3个是乳糖阳性沙门氏菌。并被鉴定为大肠杆菌;另一个是乳糖阳性,丙二酸阴性的肠炎沙门氏菌亚种。被鉴定为大肠杆菌的亚利桑那菌株。在103例发酵葡萄糖和非发酵葡萄糖的非肠胃菌株中,正确鉴定出88株(85.4%),其概率水平从优良到良好,正确鉴定出10株(9.7%),但判别水平低,总共这个小组的准确度是95.1%。未鉴定出两种菌株,而误认了三株。错误发生在三个不同属的菌株中。随着Vitek 2仪器的自动操作方法的增加,ID-GNB卡识别肠道微生物的准确度达到93%,非肠道微生物识别的准确度达到95.1%,使用该产品提供了一种可接受的识别方法临床实验室中通常分离出的大多数革兰氏阴性生物。将这些结果与通过Vitek GNI +卡测试454相同菌株所获得的结果进行比较,发现两张卡准确识别这些生物的能力没有显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号