首页> 外文OA文献 >Comparison of Multiple-Locus Variable-Number Tandem-Repeat Analysis with Pulsed-Field Gel Electrophoresis, spa Typing, and Multilocus Sequence Typing for Clonal Characterization of Staphylococcus aureus Isolates
【2h】

Comparison of Multiple-Locus Variable-Number Tandem-Repeat Analysis with Pulsed-Field Gel Electrophoresis, spa Typing, and Multilocus Sequence Typing for Clonal Characterization of Staphylococcus aureus Isolates

机译:脉冲场凝胶电泳,spa分型和多基因座序列分型用于金黄色葡萄球菌分离株克隆鉴定的多位点可变数目串联重复分析的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Multiple-locus variable-number tandem-repeat analysis (MLVA), a new PCR-based method of typing Staphylococcus aureus, was compared to pulsed-field gel electrophoresis (PFGE), spa typing, and multilocus sequence typing (MLST) on a group of 59 S. aureus (mostly methicillin-resistant) clinical isolates. The aim of the study was to establish possible criteria of clustering MLVA patterns and to check concordance levels between the results produced by MLVA and the three other typing methods. As in our earlier study, MLVA turned out to have discriminatory power similar to that of PFGE. Comparison of data obtained by the two approaches allowed us to propose a 70% or ca. 80% cutoff value of the similarity between two MLVA patterns, depending on a cutoff level applied to interpret the PFGE results, 75% or ca. 90%, respectively. The cutoff values corresponded to the difference of up to six or four bands, respectively, among maximum 14 bands in total produced by two isolates in the analysis. The MLVA clusters matched well those obtained by PFGE, and they were also consistent in general with clusters generated by spa typing and MLST, these latter methods characterized lower resolution. Our results suggest that MLVA may be reliable in shorter-term S. aureus epidemiological studies, including analyses of outbreaks and hospital-to-hospital strain transmission events. Well-known advantages of typing methods based on PCR (low cost, short time, and easiness of performance) make MLVA a method that may be useful in a variety of laboratories, including those performing routine microbiological analyses within medical centers.
机译:将多位点可变数目串联重复分析(MLVA)(一种基于PCR的新金黄色葡萄球菌分型方法)与脉冲场凝胶电泳(PFGE),spa分型和多位点序列分型(MLST)进行了比较59株金黄色葡萄球菌(多数耐甲氧西林)临床分离株。该研究的目的是建立对MLVA模式进行聚类的可能标准,并检查MLVA产生的结果与其他三种打字方法之间的一致性水平。正如我们之前的研究一样,MLVA具有与PFGE相似的歧视能力。通过两种方法获得的数据的比较使我们提出了70%或大约70%的结论。两个MLVA模式之间相似度的80%临界值,取决于用来解释PFGE结果的临界值,即75%或大约。分别为90%。截止值分别对应于分析中两个分离物产生的总共14条带中的最多6条或4条带的差异。 MLVA群集与通过PFGE获得的群集非常匹配,并且通常也与通过spa类型和MLST生成的群集一致,这些后一种方法的特征在于分辨率较低。我们的结果表明,MLVA在短期的金黄色葡萄球菌流行病学研究中可能是可靠的,包括对暴发和医院间至医院间菌株传播事件的分析。基于PCR的分型方法的众所周知的优势(成本低,时间短,操作简便)使MLVA成为可在各种实验室(包括在医疗中心内进行常规微生物分析的实验室)中使用的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号