首页> 外文OA文献 >Quantitation of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Cell-Free Cervicovaginal Secretions: Comparison of Reverse Transcription-PCR Amplification (AMPLICOR HIV-1 MONITOR 1.5) with Enhanced-Sensitivity Branched-DNA Assay (Quantiplex 3.0)
【2h】

Quantitation of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Cell-Free Cervicovaginal Secretions: Comparison of Reverse Transcription-PCR Amplification (AMPLICOR HIV-1 MONITOR 1.5) with Enhanced-Sensitivity Branched-DNA Assay (Quantiplex 3.0)

机译:无细胞子宫颈阴道分泌物中人类免疫缺陷病毒1型(HIV-1)RNA的定量:逆转录PCR扩增(AMPLICOR HIV-1 MONITOR 1.5)与敏感性增强的分支DNA分析的比较(Quantiplex 3.0)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Two commercially available hypersensitive assays for human immunodeficiency virus type 1 (HIV-1) RNA quantitation, AMPLICOR HIV-1 Monitor Test 1.5 and Quantiplex HIV RNA 3.0, were compared to detect and quantify HIV-1 RNA in the cell-free fraction of cervicovaginal secretions collected by vaginal washing. Three panel specimens were used: pooled cervicovaginal secretions spiked with HIV-1 subtype A or HIV-1 subtype B and cervicovaginal lavages from HIV-positive and HIV-negative women. Compared to the AMPLICOR HIV-1 Monitor Test 1.5 assay, the Quantiplex HIV-1 3.0 assay yielded higher estimates of HIV-1 RNA concentrations in several tested samples spiked with HIV-1 RNA subtype A, as well as subtype B, particularly samples containing low amounts of HIV-1 RNA. The sensitivity and specificity of the AMPLICOR HIV-1 Monitor Test 1.5 assay were 93 and 100%, respectively; the sensitivity and specificity of the Quantiplex HIV RNA 3.0 assay were 97 and 50%, respectively. In conclusion, in quantifying HIV-1 RNA in cervicovaginal secretions, the Quantiplex HIV RNA 3.0 may lack specificity, and the AMPLICOR HIV-1 Monitor Test 1.5 assay, although highly specific, may lack sensitivity.
机译:比较了两种市售的人类免疫缺陷病毒1型(HIV-1)RNA定量超敏检测方法AMPLICOR HIV-1 Monitor Test 1.5和Quantiplex HIV RNA 3.0,以检测和定量宫颈无阴道部分中的HIV-1 RNA。阴道冲洗收集的分泌物。使用了三个样本标本:混合有掺有HIV-1亚型A或HIV-1亚型B的宫颈阴道分泌物和来自HIV阳性和HIV阴性妇女的宫颈阴道灌洗液。与AMPLICOR HIV-1 Monitor Test 1.5分析相比,Quantiplex HIV-1 3.0分析在掺有HIV-1 RNA亚型A和B亚型的几个测试样品中,特别是在含有少量的HIV-1 RNA。 AMPLICOR HIV-1 Monitor Test 1.5检测的灵敏度和特异性分别为93%和100%。 Quantiplex HIV RNA 3.0检测的灵敏度和特异性分别为97%和50%。总之,在定量宫颈阴道分泌物中的HIV-1 RNA时,Quantiplex HIV RNA 3.0可能缺乏特异性,而AMPLICOR HIV-1 Monitor Test 1.5测定法虽然特异性很高,但可能缺乏敏感性。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号