首页> 外文OA文献 >Intersample fluctuations in phosphocreatine concentration determined by 31P-magnetic resonance spectroscopy and parameter estimation of metabolic responses to exercise in humans
【2h】

Intersample fluctuations in phosphocreatine concentration determined by 31P-magnetic resonance spectroscopy and parameter estimation of metabolic responses to exercise in humans

机译:通过31P磁共振波谱和人体对运动的代谢反应参数估计确定的磷酸肌酸浓度的样本间波动

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The ATP turnover rate during constant-load exercise is often estimated from the initial rate of change of phosphocreatine concentration ([PCr]) using 31P-magnetic resonance spectroscopy (MRS). However, the phase and amplitude characteristics of the sample-to-sample fluctuations can markedly influence this estimation (as well as that for the time constant (τ) of the [PCr] change) and confound its physiological interpretation especially for small amplitude responses.This influence was investigated in six healthy males who performed repeated constant-load quadriceps exercise of a moderate intensity in a whole-body MRS system. A transmit- receive surface coil was placed under the right quadriceps, allowing determination of intramuscular [PCr]; pulmonary oxygen uptake (V̇O2) was simultaneously determined, breath-by-breath, using a mass spectrometer and a turbine volume measuring module.The probability density functions (PDF) of [PCr] and V̇O2 fluctuations were determined for each test during the steady states of rest and exercise and the PDF was then fitted to a Gaussian function. The standard deviation of the [PCr] and V̇O2 fluctuations at rest and during exercise (sr and sw, respectively) and the peak centres of the distributions (xcr and xcw) were determined, as were the skewness (γ1) and kurtosis (γ2) coefficients.There was no difference between sr and sw for [PCr] relative to the resting control baseline (sr= 1.554%Δ (s.d.= 0.44), sw= 1.514%Δ (s.d.= 0.35)) or the PDF peak centres (xcr=−0.013 %Δ (s.d.= 0.09), xcw−0.197 %Δ (s.d.= 0.18)). The standard deviation and peak centre of the ‘noise’ in V̇O2 also did not vary between rest and exercise (sr= 0.0427 l min−1 (s.d.= 0.0104), sw= 0.0640 l min−1 (s.d.= 0.0292); xcr=−0.0051 l min−1 (s.d.= 0.0069), xcw 0.0022 l min−1 (s.d.= 0.0034)).Our results demonstrate that the intersample ‘noise’ associated with [PCr] determination by 31P-MRS may be characterised as a stochastic Gaussian process that is uncorrelated with work rate, as previously described for V̇O2. This ‘noise’ can significantly affect the estimation of τ[PCr] and especially the initial rate of change of [PCr], i.e. the fluctuations can lead to variations in estimation of the initial rate of change of [PCr] of more than twofold, if the inherent ‘noise’ is not accounted for. This ‘error’ may be significantly reduced in such cases if the initial rate of change is estimated from the time constant and amplitude of the response.
机译:恒定负荷运动期间的ATP周转率通常是使用31P磁共振波谱(MRS)根据磷酸肌酸浓度([PCr])的初始变化率估算的。但是,样本间波动的相位和幅度特征会明显影响此估计(以及[PCr]变化的时间常数(τ)的估计),并且会混淆其生理学解释,尤其是对于小幅度响应。在六名健康男性中研究了这种影响,这些男性在全身MRS系统中进行了中等强度的反复恒负荷股四头肌锻炼。将发射-接收表面线圈放置在右股四头肌下方,从而可以确定肌内[PCr]。使用质谱仪和涡轮机容量测量模块,通过呼吸同时测定肺中的氧气摄入量(V̇O2)。在稳定状态下,每次测试的[PCr]和V̇O2涨落的概率密度函数(PDF)均被确定。休息和运动,然后将PDF拟合为高斯函数。确定了[PCr]和V̇O2波动的标准偏差(分别在静止和运动期间),分别确定了分布的峰值中心(xcr和xcw)以及偏度(γ1)和峰度(γ2)相对于静止对照基线(sr = 1.554%Δ(sd = 0.44),sw = 1.514%Δ(sd = 0.35))或PDF峰中心(xcr),[PCr]的sr和sw之间没有差异。 = -0.013%Δ(sd = 0.09),xcw-0.197%Δ(sd = 0.18))。在休息和锻炼之间,V̇O2中“噪声”的标准偏差和峰值中心也没有变化(sr = 0.0427 l min-1(sd = 0.0104),sw = 0.0640 l min-1(sd = 0.0292); xcr = −0.0051 l min-1(sd = 0.0069),xcw 0.0022 l min-1(sd = 0.0034))。我们的结果表明,与31P-MRS测定[PCr]相关的样本间``噪声''可表征为随机高斯过程与工作速率无关,如先前针对V̇O2所述。这种“噪声”会显着影响τ[PCr]的估计,尤其是[PCr]的初始变化率,即,波动会导致[PCr]的初始变化率的估计变化多于两倍,如果不考虑固有的“噪音”。如果根据响应的时间常数和幅度来估算初始变化率,则可以大大减少这种“错误”。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号