首页> 外文OA文献 >Intravenous infusion bottle plugs as a source of microbial contamination.
【2h】

Intravenous infusion bottle plugs as a source of microbial contamination.

机译:静脉输液瓶塞是微生物污染的来源。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A technique was described for the artificial contamination of the upper surface of intravenous infusion container plugs with viable micro-organisms. This technique was employed to assess the adequacy of decontamination of two designs of plug by the use of antiseptic swabbing. Results indicated that the MRC plug surface was more difficult to sterilize than that of the Travenol plug. The possibility of contamination of the infusion fluid during insertion of the giving-set needle was examined. Results indicated that there was a risk of contamination through the administration-set port of the MRC plug if swabbing was inadequate.
机译:描述了一种用活微生物人工污染静脉输液容器塞上表面的技术。这项技术被用来评估通过消毒擦拭对两种设计的塞子进行去污的充分性。结果表明,MRC堵头表面比Travenol堵头更难消毒。检查了在插入针具期间污染输液的可能性。结果表明,如果擦拭不充分,则有可能通过MRC堵头的管理设定端口受到污染。