首页> 外文OA文献 >Evaluation of a Low-Cost Electrostatic Dust Fall Collector for Indoor Air Endotoxin Exposure Assessment▿
【2h】

Evaluation of a Low-Cost Electrostatic Dust Fall Collector for Indoor Air Endotoxin Exposure Assessment▿

机译:用于室内空气内毒素暴露评估的低成本静电除尘器的评估▿

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Exposure to endotoxin in home environments has become a key issue in asthma and allergy research. Most studies have analyzed floor or mattress dust endotoxin, but its validity as a proxy for airborne exposure is unknown, while active airborne dust sampling is not feasible in large-scale population studies because of logistic and financial limitations. We therefore developed and evaluated a simple passive airborne dust collection method for airborne endotoxin exposure assessment. We explored an electrostatic dust fall collector (EDC), consisting of a 42- by 29.6-cm-sized folder with four electrostatic cloths exposed to the air. The EDC was tested during two 14-day periods in seven nonfarm and nine farm homes and in farm stables. In parallel, active airborne dust sampling was performed with Harvard impactors and floor dust collected by vacuuming, using nylon sampling socks. The endotoxin levels could be measured in all EDC cloth extracts. The levels (in EU/m2) between EDCs used simultaneously or in different sampling periods in the same home correlated strongly (r > 0.8). EDC endotoxin also correlated moderately to strongly (r = 0.6 to 0.8) with the endotoxin measured by active airborne dust sampling and living room floor dust sampling and—in farm homes—with the endotoxin captured by the EDC in stables. In contrast, endotoxin levels measured by floor dust sampling showed only a poor correlation with the levels measured by active airborne dust sampling. We therefore conclude that measuring endotoxin levels with the EDC is a valid measure of average airborne endotoxin exposure, while reproducibility over time is at least equivalent to that of reservoir dust analyses.
机译:在家庭环境中接触内毒素已成为哮喘和过敏研究的关键问题。大多数研究都分析了地板或床垫上的灰尘内毒素,但其作为空气传播的替代物的有效性尚不明确,而由于后勤和财务方面的限制,在大规模人群研究中无法进行主动的空气灰尘采样。因此,我们开发并评估了一种简单的被动式机载灰尘收集方法,用于评估机载内毒素的暴露程度。我们探索了一种静电除尘器(EDC),该静电除尘器由一个42 x 29.6厘米大小的文件夹和四块暴露于空气的静电布组成。在两个14天的时间内对EDC进行了7个非农和9个农场房屋以及农场马s的测试。同时,使用哈佛撞击器对空气中的灰尘进行主动采样,并使用尼龙采样袜通过吸尘收集地板灰尘。可以测量所有EDC布提取物中的内毒素水平。同一家庭中同时使用或在不同采样期间使用的EDC之间的水平(以EU / m2为单位)密切相关(r> 0.8)。 EDC内毒素与通过主动空中尘埃采样和起居室地板灰尘采样以及在农家中通过EDC在马s中捕获的内毒素所测得的内毒素也具有中等至强相关性(r = 0.6至0.8)。相比之下,通过地板灰尘采样所测量的内毒素水平与通过主动空气传播灰尘采样所测量的水平仅显示出较弱的相关性。因此,我们得出结论,用EDC测量内毒素水平是平均空气传播的内毒素暴露的有效量度,而随着时间的推移,重现性至少等于储集层粉尘分析的重现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号