In breast tomosynthesis a rapid sequence of N images is acquired when the x-ray tube sweeps through different angular views with respect to the breast. Since the total dose to the breast is kept the same as that in regular mammography, the exposure used for each image of tomosynthesis is 1∕N. The low dose and high frame rate pose a tremendous challenge to the imaging performance of digital mammography detectors. The purpose of the present work is to investigate the detector performance in different operational modes designed for tomosynthesis acquisition, e.g., binning or full resolution readout, the range of view angles, and the number of views N. A prototype breast tomosynthesis system with a nominal angular range of ±25° was used in our investigation. The system was equipped with an amorphous selenium (a-Se) full field digital mammography detector with pixel size of 85 μm. The detector can be read out in full resolution or 2×1 binning (binning in the tube travel direction). The focal spot blur due to continuous tube travel was measured for different acquisition geometries, and it was found that pixel binning, instead of focal spot blur, dominates the detector modulation transfer function (MTF). The noise power spectrum (NPS) and detective quantum efficiency (DQE) of the detector were measured with the exposure range of 0.4–6 mR, which is relevant to the low dose used in tomosynthesis. It was found that DQE at 0.4 mR is only 20% less than that at highest exposure for both detector readout modes. The detector temporal performance was categorized as lag and ghosting, both of which were measured as a function of x-ray exposure. The first frame lags were 8% and 4%, respectively, for binning and full resolution mode. Ghosting is negligible and independent of the frame rate. The results showed that the detector performance is x-ray quantum noise limited at the low exposures used in each view of tomosynthesis, and the temporal performance at high frame rate (up to 2 frames per second) is adequate for tomosynthesis.
机译:在乳房断层合成中,当X射线管扫过相对于乳房的不同角度视图时,会获得N幅图像的快速序列。由于乳房的总剂量与常规乳腺X线摄影术相同,因此用于断层合成的每个图像的曝光量为1 ∕ N。低剂量和高帧频对数字乳腺X射线摄影探测器的成像性能提出了巨大挑战。本工作的目的是调查为层析合成采集而设计的不同操作模式下的检测器性能,例如装仓或全分辨率读数,视角范围和视角数N。标称的乳房层析合成系统原型我们的研究使用±25°的角度范围。该系统配备了像素尺寸为85μm的非晶态硒(a-Se)全场数字乳腺X线摄影检测器。探测器可以全分辨率或2×1分档(沿管行进方向分档)读取。对于不同的采集几何形状,测量了由于连续电子管行进而引起的焦点模糊,并且发现像素合并而不是焦点模糊在检测器调制传递函数(MTF)中占主导地位。检测器的噪声功率谱(NPS)和检测量子效率(DQE)在0.4-6 mR的暴露范围内测量,这与层析合成中使用的低剂量有关。发现在两种检测器读数模式下,0.4 mR的DQE仅比最高曝光下的DQE低20%。检测器的时间性能分为滞后和重影,它们均根据X射线曝光进行了测量。对于像素合并和全分辨率模式,第一帧延迟分别为8%和4%。重影可以忽略不计,并且与帧速率无关。结果表明,检测器的性能是X射线量子噪声限制在每个断层合成视图中使用的低曝光量,并且在高帧速率(每秒最多2帧)下的时间性能足以进行断层合成。

著录项

  • 作者

    Zhao, Bo; Zhao, Wei;

  • 作者单位
  • 年度 2008
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号