Sensitivity to interaural time difference (ITD) in constant-amplitude pulse trains was measured in four sequentially implanted bilateral cochlear implant (CI) subjects. The sensitivity measurements were made as a function of time beginning directly after the second ear was implanted, continued for periods of months before subjects began wearing bilateral sound processors, and extended for months while the subjects used bilateral sound processors in day-to-day listening. Measurements were also made as a function of the relative position of the left∕right electrodes. The two subjects with the shortest duration of binaural deprivation before implantation demonstrated ITD sensitivity soon after second-ear implantation (before receiving the second sound processor), while the other two did not demonstrate sensitivity until after months of daily experience using bilateral processors. The interaural mismatch in electrode position required to decrease ITD sensitivity by a factor of 2 (half-width) for CI subjects was five times greater than the half-width for interaural carrier-frequency disparity in normal-hearing subjects listening to sinusoidally amplitude-modulated high-frequency tones. This large half-width is likely to contribute to poor binaural performance in CI users, especially in environments with multiple broadband sound sources.
机译:在四个连续植入的双侧人工耳蜗(CI)受试者中,测量了恒定振幅脉冲序列对耳间时间差(ITD)的敏感性。灵敏度的测量是时间的函数,从第二只耳朵植入后立即开始,持续了几个月的时间,直到受试者开始佩戴双边声音处理器,然后持续数月,而受试者在日常聆听中使用双边声音处理器。还根据左右电极的相对位置进行测量。植入前双耳剥夺持续时间最短的两个受试者在第二耳植入后不久(在接受第二个声音处理器之前)表现出ITD敏感性,而其他两个直到使用双边处理器几个月的日常经验后才表现出敏感性。对于CI受试者,将ITD灵敏度降低2倍(半角)所需的电极位置的耳间失配比在正弦振幅调制的正常听觉受试者中,耳间载频差异的半角大五倍高频音调。这种较大的半宽度可能会导致CI用户的双耳性能不佳,尤其是在具有多个宽带声源的环境中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号